Table 12.4  
S29GL-P Sector Protection Command Definitions, x8
Command (Notes)
C
Bus Cycles (Notes 
1
–
5
)
First/Seventh
Second/Eighth
Third
Fourth
Fifth
Sixth
Addr
Data
Addr
Data
Addr
Data
Addr
Data
Addr
Data
Addr
Data
L
Command Set Entry
3
AAA
AA
555
55
AAA
40
Bits Program 
(6)
2
XXX
A0
XXX
DATA
Read 
(6)
1
00
DATA
Command Set Exit (
7
, 
8
)
2
XXX
90
XXX
00
P
Command Set Entry
3
AAA
AA
555
55
AAA
60
Password Program 
(9)
2
XXX
A0
PWA x
PWD x
Password Read 
(10)
8
00
PWD0
01
PWD 1
02
PWD 2
03
PWD 3
04
PWD 4
05
PWD 5
06
PWD 6
07
PWD 7
Password Unlock 
(10)
11
00
25
00
03
00
PWD 0
01
PWD 1
02
PWD 2
03
PWD 3
04
PWD 4
05
PWD 5
06
PWD 6
07
PWD 7
00
29
Command Set Exit (
7
, 
8
)
2
XXX
90
XXX
00
N
PPB Command Set Entry
3
AAA
AA
55
55
AAA
C0
PPB Program (
11
, 
12
)
2
XXX
A0
SA
00
All PPB Erase 
(13)
2
XXX
80
00
30
PPB Status Read 
(12)
1
SA
RD(0)
PPB Command Set Exit (
7
, 
8
)
2
XXX
90
XXX
00
G
V
PPB Lock Command Set Entry
3
AAA
AA
555
55
AAA
50
PPB Lock Bit Set 
(12)
2
XXX
A0
XXX
00
PPB Lock Status Read 
(12)
1
XXX
RD(0)
PPB Lock Command Set Exit (
7
, 
8
)
2
XXX
90
XXX
00
V
DYB Command Set Entry
3
AAA
AA
555
55
AAA
E0
DYB Set (
11
, 
12
)
2
XXX
A0
SA
00
DYB Clear 
(12)
2
XXX
A0
SA
01
DYB Status Read 
(12)
1
SA
RD(0)
DYB Command Set Exit (
7
, 
8
)
2
XXX
90
XXX
00
Legend
X = Don’t care
RD(0) = Read data. 
SA = Sector Address. Address bits A
max
–A16 uniquely select any sector.
PWD = Password
Notes
1. See 
Table 7.1 on page 19
 for description of bus operations.
2. All values are in hexadecimal.
3. All bus cycles are write cycles unless otherwise noted.
4. Data bits DQ15-DQ8 are don’t cares for unlock and command cycles.
5. Address bits A
MAX
:A16 are don’t cares for unlock and command cycles, 
unless SA or PA required. (A
MAX
 is the Highest Address pin.)
6. All Lock Register bits are one-time programmable. Program state = “0” and 
the erase state = “1.” The Persistent Protection Mode Lock Bit and the 
Password Protection Mode Lock Bit cannot be programmed at the same 
time or the Lock Register Bits Program operation aborts and returns the 
device to read mode. Lock Register bits that are reserved for future use 
default to “1’s.” The Lock Register is shipped out as “FFFF’s” before Lock 
Register Bit program execution.
PWD
x
 = Password word0, word1, word2, and word3.
Data = Lock Register Contents: PD(0) = Secured Silicon Sector Protection Bit, 
PD(1) = Persistent Protection Mode Lock Bit, PD(2) = Password Protection 
Mode Lock Bit.
7. The Exit command returns the device to reading the array.
8. If any Command Set Entry command was written, an Exit command must 
be issued to reset the device into read mode.
9. For PWDx, only one portion of the password can be programmed per each 
“A0” command.
10.Note that the password portion can be entered or read in any order as long 
as the entire 64-bit password is entered or read.
11.If ACC = V
HH
, sector protection matches when ACC = V
IH
.
12.Protected State = “00h,” Unprotected State = “01h.”
13.The All PPB Erase command embeds programming of all PPB bits before 