Stock items
are marked
by
bold printed
order numbers.
RAFIX 16
2 - 62
Control components
2
RAFIX
16
RAFIX 16 contact blocks with silver contacts
with contact block
Technical data
Dimensions
Length
Width
Height
Mounting depth (with
actuator / indicator)
22.2 mm
22.2 mm
34.4 mm
44.7 mm
Mechanical design
Mounting
Contact system
snap on actuator
bridgecontact self
cleaning
Ag
see order block
see order block
see order block
quick connector 2.8 x 0.8
according to DIN 50013,
X1 = +, X2 = -
3 mm
100 N
Contact materials
Contact arrangement
Contact function
Lamp socket
Terminals
Terminal marking
Operating travel
Robustness
Mechanical characteristics
Robustness
acc. IEC 60947-5-5
Electrical characteristics
Rated insulation voltage
acc. to VDE 0110, AC
Rated insulation voltage
acc. to VDE 0110, DC
Ohmic rated current
I
R
Rated motor current
I
Application category
acc. to VDE 0660 Teil 200
Application category
acc. to VDE 0660 Teil 200
Rated insulation voltage
U
, AC
Rated insulation voltage
U
I
, DC
Rated voltage
U
E
/ Rated current I
E
, AC
Rated voltage
U
E
/ Rated current I
E
,DAC
250 V
300 V
6 A
4 A
AC 15B 300 V
DC 13Q 300 V
250 V
300 V
250 V/1,5 A, 120 V/3,0 A V
250 V/0,27 A, 125 V/0,55 A,
60 V/1 A, 24 V/2 A V
Thermic rated current
I
the
, AC
Thermic rated current
I
the
, DC
Operating life switching
element AC
Operating life switching
element DC
5 A
2.5 A
100000 at 6A, 800000 at 2A
250000 at 220 V/0.2 A,
1000000 at 24 V/2 A
10 x I
E
1.1 x I
E
Rated power DC
Rated power AC
Contact resistance when
new max.
20 m
Other specifications
Protection class
Approvals
II
ENEC 25 T 70 (55), UL,
CSA
Corresponding to EU
directive N 72/73
Shock resistance acc. to
IEC 60068-2-27
yes
amplitude < 50g, 11ms,
half sinusoidal
Ambient temp. operating
min.
Ambient temp. operating
without lamp max.
Ambient temp. operating
with lamp max.
Storage temperature min.
Storage temperature max.
Colour code
Resistance to constant
environment
-25
°
C
+70
°
C
+55
°
C
-40
°
C
+85
°
C
grey bottom
according to
IEC 600 68-2-3 and 2-30
Resistance at variable
environment
according to
IEC 600 68-2-14 and 2-33
Mechanical operating
life latching (operations)
Resistance to vibrations
acc. to IEC 60068-2-6
Flame class acc. to UL 94
Hot wire ignition acc.
to IEC 60695-2-1
100000
10 g at 20 ... 500 Hz
V 0
yes