R1224N
TIMING CHART 
V
OUT
 Set Output Voltage
UVLO Voltage
Input Voltage 
Rising Time 
UVLO Reset 
V
OUT
 Set Output Voltage
Protection Circuit Delay Time
V
OUT
 Set Output 
Voltage 
V
IN
CE 
EXT 
V
OUT
V
OUT
 Set Output 
Voltage 
Stable 
Operation
Stable 
Operation
Stable 
Operation 
Soft Start 
Soft Start
Soft Start
Soft Start 
Reset Protection
The timing chart shown above describes the changing process of input voltage rising, stable operating, 
operating with large current, stable operating, input voltage falling, input voltage recovering, and stable 
operating. 
First, until when the input voltage (V
IN
) reaches UVLO voltage, the circuit inside keeps the condition of 
pre-standby. 
Second, after V
IN
 becomes beyond the UVLO threshold, soft-start operation starts, when the soft-start 
operation finishes, the operation becomes stable. 
If too large current flows through the circuit because of short or other reasons, EXT signal ignores that during 
the delay time of protection circuit. (The current value depends on the circuit.) 
After the delay time passes, reset protection works, or EXT signal will be “H”, then output will turn off, then 
soft-start operation starts. After the soft-start operation, EXT signal will be “L”, but if the large current is still 
flowing, after the delay time of protection circuit passes, reset protection circuit will work again, the operation will 
be continuously repeated unless the cause of large current flowing is not removed. 
Once the cause of the large current flowing is removed, within the delay time, the operation will be back to the 
stable one. 
If the timing for release the large current is in the protection process, the operation will be back to the normal 
one after the soft-start operation. 
If the V
IN
 becomes lower than the set V
OUT
, that situation is same as large current condition, so protection 
circuit may be ready to work, therefore, after the delay time of protection circuit, EXT will be “H”. 
Further, if the V
IN
 is lower than UVLO voltage, the circuit inside will be stopped by UVLO function. 
After that, if V
IN
 rises, until when the V
IN
 reaches UVLO voltage, the circuit inside keeps the condition of 
spre-standby. 
Then after V
IN
 becomes beyond the UVLO threshold, soft-start operation starts, when the soft-start operation 
finishes, the operation becomes stable. 