6 Appendix
6.1 Wavecom acceptance test
These tests are Wavecom internal qualification tests. They are performed on a
Wavecom evaluation platform (module on test board).
Test
Applied standard
Acceptance criteria
Performance
Test
Mobile Station (MS) conformance
specification; Part 1:
Conformance
(Release 5).
3GPP TS 51.010 v5.0.0 (2002-09)
specification
Full conformity to the recommendation regarding
the main RF parameters.
Cooking Test
-
The test continues even after the Cooking Test
milestone has been reached
Stress Test
Therma shocks IEC 68-2-14.
Full conformity to the recommendation regarding
the main parameters.
Vibration Test
Sinusoidal vibration IEC 68-2-6.
No performance degradation or mechanical
degradation is allowed after test.
Vibration Test
Random vibration IEC 68-2-36.
No performance degradation or mechanical
degradation is allowed after test.
Shock Test
IEC 68-2-27.
No performance degradation or mechanical
degradation is allowed after test.
Bump Test
IEC 68-2-29.
No performance degradation or mechanical
degradation is allowed after test.
Humidity Test
Corrosion test IEC 68-2-3.
No visible degradation of the product, both
visual and functionnal.
The unit is tested at room temperature and must
be fully operative for the main RF parameters.
Warehouse
Test
Low temperance IEC 68-2-1.
Under normal condition (room temperature) after
the test, the unit must behave in full conformity
with the main RF parameters specification.
Warehouse
Test
High temperature IEC 68-2-2.
Under normal condition (room temperature) after
the test, the unit must behave in full conformity
with the main RF parameters specification.
Dust Test1
MIL-STD-810D, method 510-3.
No visible dust in the visible areas. No more than
50 dust particules in the cabinet of the product.
The unit, tested at room temperature must be
fully operative.
Light Test1
UV radiation and temperature EDF
HN60E03.
Visual inspection on the discoloration and other
degradation effects such as cracks in the
material of the unit after the test.
Fall Test1
IEC 68-2-32.
Only minor casing degradation is allowed, with a
maximum dimension change of 1mm. The unit
must remain fully operative and full specification
for the main RF parameters.