PW070XS1
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd.
PAGE:22
12. Reliability Test
No
1
2
3
4
Test Item
Test Condition
Ta = +95
Ta = -40
Ta = +85
Ta = -30
High Temperature Storage Test
Low Temperature Storage Test
High Temperature Operation Test
Low Temperature Operation Test
High Temperature & High Humidity
Operation Test
Thermal Cycling Test
(non-operating)
, 240 hrs
, 240 hrs
, 240 hrs
, 240 hrs
5
Ta = +60
, 90%RH, 240 hrs
6
-30
+80
, 200 Cycles
30 min 30 min
Frequency
7
Vibration Test
(non-operating)
10 ~ 55 H
Z
1 mm
Amplitude
Sweep time: 11 mins
Test Period: 6 Cycles for each direction of X, Y, Z
100G, 6ms
Direction: X, Y, Z
Cycle: 3 times
200pF , 0
200V
1 time / each terminal
8
Shock Test
(non-operating)
9
Electrostatic Discharge Test
(non-operating)
Ta: ambient temperature
[Criteria]
Under the display quality test conditions with normal operation state, there should be no change
which may affect practical display function.
13. Indication of Lot Number Label
a) Indicated contents of the label
Lot number
Module number
Contents of lot number : 1st~3rd—The OEM product
OOO-OOOOOO
PW070XS1XXS
5th—Production year : 1999
9, 2000
A, 2001
B……..
6th—Production month : 1, 2, 3,….9, A, B, C
7th~8th—Production size : 7.0”
70
9th~10th—Serial numbers : 01~99