MITSUMI
System Reset PST591~595
Measuring Circuit
[1]
[2]
Electrical Characteristics
(Ta=25
°
C) (Except where noted otherwise, resistance unit is
)
*
1 tpLH : V
CC
= (V
S
typ.
-
0.4V) (V
S
typ.+0.4V), tpHL : V
CC
= (V
S
typ.+0.4V) (V
S
typ.
-
0.4V)
*
2 V
CC
=V
S
min.
-
0.15V
Note 3: V
OUT
pin is low when manual reset pin is high.
V
OUT
pin is high when manual reset pin is low.
Note: Input model is an example for PST591C.
Item
Symbol
Measuring circuit
Measurement conditions
Min. Typ. Max. Unit
4.3
4.5
4.0
4.2
3.7
3.9
3.4
3.6
3.1
3.3
2.9
3.1
2.75 2.90 3.05
2.55 2.70 2.85
2.35 2.50 2.65
30
50
C
D
E
F
G
H
I
J
K
4.7
4.4
4.1
3.8
3.5
3.3
R
L
=470
V
OL
< 0.4V
V
CC
=H L
Detection voltage
V
S
1
V
Hysteresis voltage
Detection voltage
temperature coefficient
Low-level output voltage
Output leakage current
Circuit current while on
Circuit current while off
V
S
1
R
L
=470, V
CC
=L H L
100
mV
V
S
/ T
1
R
L
=470, Ta=
-
20
°
C~+75
°
C
±0.01
%/
°
C
V
OL
I
OH
I
CCL
I
CCH
1
1
1
1
V
CC
=Vs min.
-
0.05V, R
L
=470
V
CC
=10V
V
CC
=Vs min.
-
0.05V, R
L
=
∞
V
CC
=Vs typ./0.85V, R
L
=
∞
0.1
0.4
±0.1
600
350
75
150
300
600
V
μA
μA
μA
300
200
50
100
200
400
800 1200
10
0.65 0.85
PST591
PST592
PST593
PST594
PST595
30
60
120
240
480
R
L
=4.7k
C
L
=100PF
*
1
"H" transport delay time
t
PLH
2
mS
"L" transport delay time
Operating power supply voltage
Output current while on 1
Output current while on 2
Manual
Input high voltage
reset
Input high current
pin
Input low voltage
t
PHL
V
OPL
I
OL
1
I
OL
2
V
RESH
V
RESH
V
RESL
2
1
1
1
R
L
=4.7k, C
L
=100PF
*
1
R
L
=4.7k, V
OL
< 0.4V
V
CC
=V
S
min.
-
0.05V, R
L
=0
Ta=
-
20
°
C
~+75
°
C
, R
L
=0
*
2
μS
V
mA
mA
V
μA
V
8
6
2.0
V
RES
=2V
80
0.8