Technical Specification
Product # PQ50090QGB11
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005485 Rev. A
03/29/10
Page 4
Input:48V
Output:9.0V
Current:11A
Part No.:PQ50090QGB11
PQ50090QGB11 ELECTRICAL CHARACTERISTICS (continued)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 48V dc unless otherwise noted; full operating temperature range is -40 °C to +70 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
60
dB
120Hz; Figure 16
Output Voltage during Load Current Transient
Step Change in Output Current (0.1A/s)
300
mV
50% to 75% to 50% Iout max, 470 μF load cap
Step Change in Output Current (5A/s)
200
mV
Settling time
300
us
To within 1% Vout nom
Turn-On Transient
Turn-On Time
10
ms
Full load, Vout=90% nom; Figures 9 & 10
Output Voltage Overshoot
0
%
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
2000
V
See Absolute Maximum Ratings
Isolation Resistance
30
MΩ
Isolation Capacitance (input to output)
470
pF
See Note 4
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
125
°C
Package rated to 150°C
Board Temperature
125
°C
UL rated max operating temp 130°C
Transformer Temperature
125
°C
FEATURE CHARACTERISTICS
Switching Frequency Regulation Stage
290
320
350
kHz
ON/OFF Control (Option P)
Off-State Voltage
-2.0
0.8
V
On-State Voltage
2.4
18.0
ON/OFF Control (Option N)
Off-State Voltage
2.4
18
V
On-State Voltage
-2.0
0.8
ON/OFF Control (Either Option)
Application notes; Figures A & B
Pull-Up Voltage
Vin/4.25
14.30
V
Pull-Up Resistance
40
kΩ
Output Voltage Trim Range
-10
10
%
Measured across Pins 8 & 4; Figure C
Output Over-Voltage Protection
117
122
127
%
Over Full Temperature Range; % of nominial Vout
Over-Temperature Shutdown
125
°C
Average PCB Temperature
Over-Temperature Shutdown Restart Hysteresis
10
°C
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
2.50
106 Hrs. TR-NWT-000332; 80% load, 300LFM, 40°C Ta
Calculated MTBF (MIL-217)
1.56
106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40°C Ta
Field Demonstrated MTBF
106 Hrs. See our website for details
Note 1: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference.
Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 3: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode,
with a 500ms off-time.
Note 4: Higher values of isolation capacitance can be added external to the module.