Lucent Technologies Inc.
37
Data Sheet
June 1999
ORCA Series 2 FPGAs
Programmable Corner Cells
Programmable Routing
The programmable corner cell (PCC) contains the cir-
cuitry to connect the routing of the two PICs in each 
corner of the device. The PIC PX1 and PX2 lines are 
directly connected together from one PIC to another. 
The PIC PXL lines are connected from one block to 
another through tridirectional buffers. Four CIPs in 
each corner connect the four PXH lines from each side 
of the device. 
Special-Purpose Functions
In addition to routing functions, special-purpose func-
tions are located in each FPGA corner. The upper-left 
PCC contains connections to the boundary-scan logic. 
The upper-right PCC contains connections to the read-
back logic and the connectivity to the global 3-state 
signal (TS_ALL). The lower-left PCC contains connec-
tions to the internal oscillator. 
The lower-right PCC contains connections to the start-
up and global reset logic. During configuration, the 
RESET
 input pad always initiates a configuration abort, 
as described in the FPGA States of Operation section. 
After configuration, the global set/reset signal (GSRN) 
can either be disabled (the default), directly connected 
to the 
RESET
 input pad, or sourced by a lower-right 
corner signal. If the 
RESET
 input pad is not used as a 
global reset after configuration, this pad can be used as 
a normal input pad. During start-up, the release of the 
global set/reset, the release of the I/Os, and the 
release of the external DONE signal can each be timed 
individually based upon the start-up clock. The start-up 
clock can come from CCLK or it can be routed into the 
start-up block using the lower-right corner routing 
resources. More details on start-up can be found in the 
FPGA States of Operation section.
Clock Distribution Network
The ORCA Series 2 clock distribution schemes use pri-
mary and secondary clocks. This provides the system 
designer with additional flexibility in assigning clock 
input pins. 
One advantage is that board-level clock traces routed 
to the FPGA are shorter. On a PC board, the added 
length of high-speed clock traces routed to dedicated 
clock input pins can significantly increase the parasitic 
impedances. The primary advantage of the ORCA 
clock distribution is the availability of a large number of 
clocks, since all I/O pins are configurable as clocks.
Primary Clock 
The primary clock distribution is shown in Figure 34. If 
the clock signal is from an I/O pad, it can be driven onto 
a clock line. The clock lines do not provide clock signals 
directly to the PFU; they act as clock spines from which 
clocks are branched to XL lines. The XL lines then feed 
the clocks to PFUs. A multiplexer in each PLC is used 
to transition from the clock spine to the branch. 
For a clock spine in the horizontal direction, the inputs 
into the multiplexer are the two lines from the left and 
right PICs (CKL and CKR) and the local clock line from 
the perpendicular direction (HCK). This signal is then 
buffered and driven onto one of the vertical XL lines, 
forming the branches. The same structure is used for a 
clock spine in the vertical direction. In this case, the 
multiplexer selects from lines from the top and bottom 
PICs (CKT, CKB, and VCK) and drives the signal onto 
one of the horizontal XL lines.
Figure 34 illustrates the distribution of the low-skew pri-
mary clock to a large number of loads using a main 
spine and branches. Each row (column) has two dedi-
cated clock lines originating from PICs on opposite 
sides of the array. The clock is input from the pads to 
the dedicated clock line CKT to form the clock spine 
(see Figure 34, Detail A). From the clock spine, net 
branches are routed using horizontal XL lines and then 
PLC clock inputs are tapped from the XL lines, as 
shown in Figure 34, Detail B.