![](http://datasheet.mmic.net.cn/ON-Semiconductor/NLAS5113DFT2G_datasheet_99165/NLAS5113DFT2G_3.png)
NLAS5113
http://onsemi.com
3
OPERATING CONDITIONS
MAXIMUM RATINGS
Symbol
Pins
Parameter
Value
Condition
Unit
VCC
Positive DC Supply Voltage
-0.5 to 5.5
V
VIS
NOx, NCx,
COMx
Analog Signal Voltage
-0.5 to VCC + 0.5
V
VIN
IN1, IN2
Control Input Voltage
-0.5 to 6.0
V
ICC
VCC
Positive DC Supply Current
50
mA
IIS_CON
NOx, NCx,
COMx
Analog Signal Continuous Current
±300
Closed Switch
mA
IIS_PK
NOx, NCx,
COMx
Analog Signal Peak Current
±500
10% Duty Cycle
mA
IIN
IN
Control Input Current
mA
TSTG
Storage Temperature Range
-65 to 150
°C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
RECOMMENDED OPERATING CONDITIONS
Symbol
Pins
Parameter
Value
Condition
Unit
VCC
Positive DC Supply Voltage
1.65 to 4.5
V
VIS
NOx, NCx,
COMx
Analog Signal Voltage
0 to VCC
V
VIN
IN1, IN2
Control Input Voltage
0 to VCC
V
TA
Operating Temperature Range
-40 to 85
°C
NOTE:
Minimum and maximum values are guaranteed through test or design across the Recommended Operating Conditions, where
applicable. Typical values are listed for guidance only and are based on the particular conditions listed for each section, where
applicable. These conditions are valid for all values found in the characteristics tables unless otherwise specified in the test
conditions.