GENERAL DATA — 500 mW DO-35 GLASS
Motorola TVS/Zener Device Data
6-110
500 mW DO-35 Glass Data Sheet
*ELECTRICAL CHARACTERISTICS
(TL = 30
°
C unless otherwise noted.) (VF = 1.5 Volts Max @ IF = 100 mAdc for all types.)
Impedance (Ohm)
@ IZT
f = 1000 Hz
Device Type
(Note 2)
Min
Max
(mA)
(Note 3)
Zener Voltage(Note 4)
Leakage Current
(
μ
A)
Temp. Coefficient
(Typical)
(mV/
°
C)
Capacitance
(Typical)
(pF)
VR = 0,
f = 1.0 MHz
IZT=
Max
Max
@ VR=
(Volt)
Min
Max
BZX79C2V4RL
BZX79C2V7RL
BZX79C3V0RL
BZX79C3V3RL
BZX79C3V6RL
2.2
2.5
2.8
3.1
3.4
2.6
2.9
3.2
3.5
3.8
5
5
5
5
5
100
100
95
95
90
100
75
50
25
15
1
1
1
1
1
–3.5
–3.5
–3.5
–3.5
–3.5
0
0
0
0
0
255
230
215
200
185
BZX79C3V9RL
BZX79C4V3RL
BZX79C4V7RL
BZX79C5V1RL
BZX79C5V6RL
3.7
4
4.4
4.8
5.2
4.1
4.6
5
5.4
6
5
5
5
5
5
90
90
80
60
40
10
5
3
2
1
1
1
2
2
2
–3.5
–3.5
–3.5
–2.7
–2
+0.3
+1
+0.2
+1.2
+2.5
175
160
130
110
95
BZX79C6V2RL
BZX79C6V8RL
BZX79C7V5RL
BZX79C8V2RL
BZX79C9V1RL
5.8
6.4
7
7.7
8.5
6.6
7.2
7.9
8.7
9.6
5
5
5
5
5
10
15
15
15
15
3
2
1
4
4
5
5
6
0.4
1.2
2.5
3.2
3.8
3.7
4.5
5.3
6.2
7
90
85
80
75
70
0.7
0.5
BZX79C10RL
BZX79C11RL
BZX79C12RL
BZX79C13RL
BZX79C15RL
9.4
10.4
11.4
12.4
13.8
10.6
11.6
12.7
14.1
15.6
5
5
5
5
5
20
20
25
30
30
0.2
0.1
0.1
0.1
0.05
7
8
8
8
4.5
5.4
6
7
9.2
8
9
10
11
13
70
65
65
60
55
10.5
BZX79C16RL
BZX79C18RL
BZX79C20RL
BZX79C22RL
BZX79C24RL
15.3
16.8
18.8
20.8
22.8
17.1
19.1
21.2
23.3
25.6
5
5
5
5
5
40
45
55
55
70
0.05
0.05
0.05
0.05
0.05
11.2
12.6
14
15.4
16.8
10.4
12.9
14.4
16.4
18.4
14
16
18
20
22
52
47
36
34
33
BZX79C27RL
BZX79C30RL
BZX79C33RL
BZX79C36RL
BZX79C39RL
25.1
28
31
34
37
28.9
32
35
38
41
2
2
2
2
2
80
80
80
90
130
0.05
0.05
0.05
0.05
0.05
18.9
21
23.1
25.2
27.3
23.5
26
29
31
34
30
27
25
23
21
BZX79C43RL
BZX79C47RL
BZX79C51RL
BZX79C56RL
BZX79C62RL
40
44
48
52
58
46
50
54
60
66
2
2
2
2
2
150
170
180
200
215
0.05
0.05
0.05
0.05
0.05
30.1
32.9
35.7
39.2
43.4
37
40
44
47
51
21
19
19
18
17
BZX79C68RL
BZX79C75RL
BZX79C82RL
BZX79C91RL
BZX79C100RL
64
70
77
85
94
72
79
87
96
106
2
2
2
2
1
240
255
280
300
500
0.05
0.05
0.1
0.1
0.1
47.6
52.5
62
69
76
56
60
95
107
119
17
16.5
29
28
27
46
51
57
BZX79C110RL
BZX79C120RL
BZX79C130RL
BZX79C150RL
BZX79C160RL
104
114
124
138
153
116
127
141
156
171
1
1
1
1
1
650
800
950
1250
1400
0.1
0.1
0.1
0.1
0.1
84
91
99
114
122
63
69
75
87
93
131
144
158
185
200
26
24
23
21
20
BZX79C180RL
BZX79C200RL
168
188
191
212
1
1
1700
2000
0.1
0.1
137
152
105
120
228
255
18
17
NOTE 1.
Zener voltage is measured under pulse conditions such that TJ is no more than 2
°
C
above TA.
NOTE 2. TOLERANCE AND VOLTAGE DESIGNATION
Tolerance designation —– The type numbers listed have zener voltage min/max limits as
shown. Device tolerances of
±
2% are indicated by a “B” instead of a “C,” and
±
1% by “A.”
NOTE 3.
ZZT is measured by dividing the ac voltage drop across the device by the ac current