MXR2312G/M SPECIFICATIONS
(Measurements @ 25
°
C, Acceleration = 0
g
unless otherwise noted; V
DD
, V
DA
= 5.0V unless
otherwise specified)
Conditions
Min
SENSOR INPUT
Measurement Range
1
±
2.0
Nonlinearity
Best fit straight line
Alignment Error
2
X Sensor to Y Sensor
Transverse Sensitivity
3
SENSITIVITY
Sensitivity, Analog Outputs at
pins
A
OUTX
and A
OUTY
Change over Temperature
-10
ZERO
g
BIAS LEVEL
0
g
Offset
5
-0.1
0
g
Voltage
5
2.47
0
g
Offset over Temperature
Based on 312 mV/g
NOISE PERFORMANCE
Noise Density, rms
Without frequency
compensation
FREQUENCY RESPONSE
3dB Bandwidth - uncompensated
15
3dB Bandwidth – compensated
4
TEMPERATURE OUTPUT
T
out
Voltage
1.15
Sensitivity
4.6
VOLTAGE REFERENCE
V
Ref
@3.0V-5.25V supply
2.4
Change over Temperature
Current Drive Capability
Source
SELF TEST
Continuous Voltage at A
OUTX
,
A
OUTY
under Failure
rails to
supply voltage
Continuous Voltage at A
OUTX
,
A
OUTY
under Failure
rails to
supply voltage
A
OUTX
and A
OUTY
OUTPUTS
Normal Output Range
@5.0V Supply
1.0
Current
Source or sink, @
3.0V-5.25V supply
Turn-On Time
@5.0V Supply
@3.0V Supply
POWER SUPPLY
Operating Voltage Range
3.0
Supply Current
@ 5.0V
2.7
Supply Current
@ 3.0V
3.2
TEMPERATURE RANGE
Operating Range
0
NOTES
1
Guaranteed by measurement of initial offset and sensitivity.
MEMSIC MXR2312G/M Rev.E
Page 2 of 6
1/19/2005
Parameter
MXR2312G
Typ
Max
Min
±
2.0
296
MXR2312M
Typ
Max
Units
g
% of FS
degrees
%
mV/
g
Each Axis
0.5
±
1.0
±
2.0
312
1.0
328
0.5
±
1.0
±
2.0
312
1.0
328
5
Each Axis
296
+8
+0.1
2.53
-25
-0.1
2.47
+8
+0.1
2.53
%
g
V
Each Axis
0.0
2.50
±
1.5
±
0.47
0.2
0.0
2.50
±
1.5
±
0.47
0.2
m
g
/
°
C
mV/
°
C
m
g
/
Hz
0.4
0.4
17
>160
1.25
5.0
2.5
0.1
5.0
19
1.35
5.4
2.65
100
15
1.15
4.6
2.4
17
>160
1.25
5.0
2.5
0.1
5.0
19
1.35
5.4
Hz
Hz
V
mV/
°
K
2.65
V
mV/
°
C
μ
A
V
100
@5.0V Supply, output
@3.0V Supply, output
3.0
3.0
V
4.0
100
1.0
4.0
100
V
μ
A
160
300
3.3
4.0
160
300
3.3
4.0
mS
mS
V
mA
mA
°
C
5.25
4.1
4.8
+70
3.0
2.7
3.2
-40
5.25
4.1
4.8
+
10
5
2
Alignment error is specified as the angle between the true and indicated axis of
sensitivity.
3
Transverse sensitivity is the algebraic sum of the alignment and the inherent
sensitivity errors.
4
External circuitry is required to extend the 3dB bandwidth (ref. Application Note:
AN-00MX-003)
5
The device operates over a 3.0V to 5.25V supply range. Please note that sensitivity
and zero
g
bias level will be slightly different at 3.0V operation. For devices to be
operated at 3.0V in production, they can be trimmed at the factory specifically for
this lower supply voltage operation, in which case the sensitivity and zero
g
bias
level specifications on this page will be met. Please contact the factory for specially
trimmed devices for low supply voltage operation.