Type
Line input voltage
Input current
Output voltage (1)
Output power (2)
Reference voltage (3)
Tirgger input: (4)
Trigger
Pulse duration
MVS-2601
115/230 ±10% VAC 50/60 Hz
(115 factory set)
1.2 amps maximum (115 VAC)
225 to 750 volts
43 watts maximum
3 to 10VDC
MVS-2602
15 to 28 VDC
4 amps peak at 24 VDC
200 to 750 volts
43 watts maximum
2 to 10 VDC
For more information e-mail us at opto@perkinelmer.com or visit our web site at
www.perkinelmer.com/opto
.
All values are nominal; specifications subject to change without notice.
2001 PerkinElmer inc. All rights reserved.
0601
.
USA:
PerkinElmer Optoelectronics
35 Congress Street
Salem, MA 01970
Toll Free: (800) 950-3441 (USA)
Phone: (978) 745-3200
Fax: (978) 745-0894
Europe:
PerkinElmer Optoelectronics
Wenzel-Jaksch-Str. 31, D-65199
Weisbaden, Germany
Phone: +49 (0) 611-492-437
Fax: +49 (0)611-492-159
Asia:
PerkinElmer Optoelectronics
47 Ayer Rajah Crescent #06-12
Singapore 139947
Phone: +65 775 2022
Fax: +65 775 1008
Spectral bandwidth (1)
Flashlamp arc length
Flash rate (2)
Flashlamp life (4)
Flash duration (2) (3)
Flash to flash variation
Light output (2)
MVS-2600 Series
300 to 1100+ nm
0.06 in (1.5mm)
60 Hz maximum
10
8
flashes
6 microseconds typical
<5%
Photometric: 2.5 lumen-sec
Radiometric: 20 mJ
Optical Specifications
Electrical Specifications
Operating temperature
Storage temperature
Shock and vibration
-10 to +110°C (-23 to +43°F)
-40 to +194°C (-40 to +90°F)
1.5 g. 5 to 20 Hz per MIL-STD 810C
Environmental Specifications
MVS-2600 Series
www.perkinelmer.com/opto
MATING INPUT
CONNECTOR(S)
SUPPLIED
7
4
4.25 (108.0)
9.25 (235.0)
8.50 (215.9)
0.218 X 0.281 MOUNTING SLOT (4 PLCS)
NEMA 13 ENCLOSURE
WEIGHT 6.5 LBS (3.0 kg)
DIMENSIONS ARE IN
INCHES (MILLIMETERS)
NOSEPIECE,
BLANK ADAPTER
AND HEAT SINK
SUPPLIED WITH
ALL MVS-2600
SERIES UNITS
Mechanical Specifications
Note 1:
Note 2:
Note 3:
Note 4:
Output measured @ front face of bulb.
Up to 20 watts with heat sink and natural convection cooling. Above 20 watts forced air cooling is required.
Output voltage may be adjusted using an external voltage reference source. MVS 2601, 75 volts per volt of reference. MVS 2602, 100 volts per volt of reference.
Delay between flash command and light output is 8 microseconds typical.
Note 1:
Note 2:
Note 3:
Note 4:
Spectral bandwidth may be extended into the ultraviolet by using other flashlamp envelope materials.
Measured at light output port, 600 VDC and 4μf. Lower energy discharge levels providing higher flash rates and lower outputs are available.
Measured at 1/3 of peak current.
While maintaining >70% of initial intensity
+5 volt pulse into opto-isolator with 150 ohm nominal series resistor
10 to 100 microseconds