RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
16 to 40 VDC continuous
50 V for up to 50 msec transient
Case Operating Temperature (Tc)
–55°C to +125°C full power
–55°C to +135°C absolute
Derating Output Power/Current (Tc)
Linearly from 100% at 125°C to 0% at 135°C
TYPICAL CHARACTERISTICS
Output Voltage Temperature Coefficient
100 ppm/°C typical
Input to Output Capacitance
50 pF typical
Isolation
100 megohm minimum at 500 V
Audio Rejection
50 dB typical
Conversion Frequency
550 kHz typical (400 kHz 60 V model)
450 kHz min, 600 kHz max
350 kHz min, 450 kHz max 60 V model
Inhibit Pin Voltage (unit enabled)
9 to 11 V
INHIBIT
ABSOLUTE MAXIMUM RATINGS
Input Voltage
16 to 40 V
Output Power
5 watts
Lead Soldering Temperature (10 sec per lead)
300°C
Storage Temperature Range (Case)
–65°C to +135°C
2
MSASERIES
5 WATT
DC/DC C
ONVERTERS
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
Inhibit TTL Open Collector
Logic low (output disabled)
Logic low voltage
≤
0.8 V max
Inhibit pin current 4 mA max
Referenced to input common
Logic high (output enabled)
Open collector
Notes
1. MSA2860S specifications are at 25°Tc only, contact your Interpoint
representative for more information on over temperature specs.
2. Line regulation for /ES and non /ES 2805S models at 16 to 17 V
IN
and 110
°C to 125°C (case) is 5% (max).
3. Indefinite short circuit protection not guaranteed above 125°C (case).
4. Recovery time is measured from application of the transient to point at which
V
is within 1% of V
OUT
at final value.
5. Transition time >10μs.
SINGLE OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
Tc = –55°C TO +125°C
OUTPUT POWER
MSA2805S
MIN TYP MAX
4.95
5.00
MSA285R2S
MIN
TYP MAX
5.15
5.20
MSA2812S
MIN
TYP
5.25 11.88 12.00 12.12 14.85 15.00 15.15
MSA2815S
MIN
TYP MAX
MSA2860S
1
MIN
TYP MAX
59.1 60.00 60.9
CONDITIONS
Tc = –55°C TO +125°C
MAX
UNITS
VDC
5.05
V
IN
= 16 TO 40 VDC
V
IN
= 16 TO 40 VDC
Tc = –55°C TO +125°C
0
—
1000
0
—
962
0
—
417
0
—
333
0
—
20
mA
—
—
5
—
—
5
—
—
5
—
—
5
—
—
1.2
W
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
10 kHz - 2 MHz
V
= 16 TO 40 VDC
Tc = –55°C TO +125°C
NO LOAD TO FULL
Tc = –55°C TO +125°C
Tc = –55°C TO +125°C
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
FULL LOAD
INHIBITED
10 kHz - 10 MHz
Tc = –55°C TO +125°C
—
125
350
—
110
335
—
50
200
—
50
170
—
—
300
mV p-p
—
10
50
2
—
10
50
—
10
50
—
10
50
—
—
300
mV
LOAD REGULATION
—
10
50
—
10
50
—
10
50
—
10
50
—
—
300
mV
INPUT VOLTAGE
NO LOAD TO FULL
16
0
—
—
—
—
—
66
—
—
28
—
27
250
3
25
30
71
1.5
12.5
40
50
40
—
5
100
150
—
2.0
25
16
0
—
—
—
—
—
66
—
—
28
—
28
250
3
25
30
71
1.5
1.5
40
50
40
—
5
100
150
—
2.0
25
16
0
—
—
—
—
—
70
—
—
28
—
29
235
3
25
30
76
1.2
1
40
50
42
—
5
100
150
—
1.9
10
16
0
—
—
—
—
—
71
—
—
28
—
31
235
3
25
30
76
1.2
1
40
50
44
—
5
100
150
—
1.8
10
16
0
—
—
—
—
—
70
—
—
28
—
—
72
3
—
—
75
—
—
40
50
30
—
5
90
—
—
—
—
VDC
V
INPUT CURRENT
Tc = –55°C TO +125°C
mA
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
3, 4
SHORT CIRCUIT
STEP LOAD
RESPONSE
4, 5
mA p-p
%
W
ms
POWER DISSIPATION
RECOVERY
50% - 100% - 50%
TRANSIENT
RECOVERY
TRANSIENT
16 TO 40 V
IN
40 TO 16 V
IN
RECOVERY
16 TO 40 V
IN
40 TO 16 V
IN
DELAY
OVERSHOOT
—
—
100
100
250
250
—
—
100
100
250
250
—
—
150
200
375
500
—
—
200
200
500
500
—
—
—
—
—
—
mV pk
μs
STEP LINE
RESPONSE
4, 5
—
—
50
50
150
150
—
—
50
50
150
150
—
—
80
100
200
250
—
—
50
50
125
125
—
—
—
—
—
—
mV pk
—
—
100
200
250
500
—
—
100
200
250
500
—
—
250
250
625
625
—
—
250
250
625
625
—
—
—
—
—
—
μs
START-UP
—
—
10
0
25
50
—
—
10
0
25
50
—
—
3
0
10
120
—
—
3
0
10
150
—
—
—
—
—
—
ms
mV pk