2
Motorola Sensor Device Data
MAXIMUM RATINGS
Rating
Symbol
Value
Unit
Overpressure(8) (P2
Burst Pressure(8) (P2
1 Atmosphere)
P1max
P1burst
Tstg
TA
2800
kPa
1 Atmosphere)
5000
kPa
Storage Temperature
–40 to +125
°
C
Operating Temperature
–40 to +125
°
C
OPERATING CHARACTERISTICS
(VCC = 10 Vdc, TA = 25
°
C unless otherwise noted. P1
Characteristic
Pressure Range(1)
Supply Voltage(2)
P2; P2
1 Atmosphere.)
Symbol
Min
Typ
Max
Unit
POP
VS
Io
VFSS
Voff
V/
P
0
—
700
kPa
—
10
16
Vdc
Supply Current
Full Scale Span(3)
Offset(4)
—
6.0
—
mAdc
38.5
40
41.5
mV
–1.0
—
1.0
mV
Sensitivity
Linearity(5)
Pressure Hysteresis(5) (0 to 700 kPa)
Temperature Hysteresis(5) (–40
°
C to +125
°
C)
Temperature Effect on Full Scale Span(5)
Temperature Effect on Offset(5)
—
0.057
—
mV/kPa
—
–0.5
—
0.5
%VFSS
%VFSS
%VFSS
%VFSS
mV
—
—
±
0.1
—
—
—
±
0.5
—
TCVFSS
TCVoff
Zin
Zout
tR
—
–1.0
—
1.0
–1.0
—
1.0
Input Impedance
1300
—
4000
Output Impedance
Response Time(6) (10% to 90%)
Warm–Up(7)
1400
—
3000
—
1.0
—
ms
—
20
—
ms
MECHANICAL CHARACTERISTICS
Characteristic
Symbol
Min
Typ
Max
Unit
Weight (Basic Element Case 344–15)
—
—
2.0
—
Grams
NOTES:
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range. Operating the device above the specified excitation range may induce additional
error due to device self–heating.
3. Full Scale Span (VFSS) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
4. Offset (Voff) is defined as the output voltage at the minimum rated pressure.
5. Accuracy (error budget) consists of the following:
Linearity:
Output deviation from a straight line relationship with pressure, using end point method, over the specified
pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is
cycled to and from the minimum or maximum operating temperature points, with zero differential pressure
applied.
Pressure Hysteresis:
Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25
°
C.
TcSpan:
Output deviation at full rated pressure over the temperature range of 0 to 85
°
C, relative to 25
°
C.
TcOffset:
Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85
°
C, relative
to 25
°
C.
6. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to
a specified step change in pressure.
7. Warm–up is defined as the time required for the device to meet the specified output voltage after the pressure has been stabilized.
8. Basic Element only, Case 344–15.
9. P2 max : 500 kPa.