MP03 XX 280 Series
6/9
0
50
100
150
Mean forward current - (A)
200
250
400
350
300
250
200
150
100
50
0
O
d.c.
120 Rectangular
180 Sine
60 Rectangular
180 Rectangular
300
350
400
0
50
100
150
Mean forward current - (A)
200
250
300
120
100
80
60
40
20
0
M
d.c.
1
1
6
140
160
1
350
400
Fig. 4 On-state power loss per arm vs forward current at various conduction angles, 50/60Hz
Fig. 5 Maximum permissible case temperature vs forward current per arm at various conduction angles, 50/60Hz