MMSZ2V4ET1 Series
http://onsemi.com
2
ELECTRICAL CHARACTERISTICS
(T
A
= 25
°
C unless
otherwise noted, V
F
= 0.95 V Max. @ I
F
= 10 mA)
Symbol
Parameter
V
Z
Reverse Zener Voltage @ I
ZT
I
ZT
Reverse Current
Z
ZT
Maximum Zener Impedance @ I
ZT
I
R
Reverse Leakage Current @ V
R
V
R
Reverse Voltage
I
F
Forward Current
V
F
Forward Voltage @ I
F
Zener Voltage Regulator
I
F
V
I
I
R
I
ZT
V
R
V
Z
V
F
ELECTRICAL CHARACTERISTICS
(T
A
= 25
°
C unless otherwise noted, V
F
= 0.9 V Max. @ I
F
= 10 mA)
V
Z1
(V)
(Notes 4 and 5)
Z
ZT1
(Note 6)
V
Z2
(V)
(Notes 4 and 5)
Z
ZT2
(Note 6)
Leakage Current
Device
Marking
@ I
ZT1
= 5 mA
@ I
ZT2
= 1 mA
I
R
@ V
R
Device
Min
Nom
Max
Min
Max
A
V
MMSZ2V4ET1
CL1
2.28
2.4
2.52
100
1.7
2.1
600
50
1
MMSZ2V7ET1
CL2
2.57
2.7
2.84
100
1.9
2.4
600
20
1
MMSZ3V0ET1
CL3
2.85
3.0
3.15
95
2.1
2.7
600
10
1
MMSZ3V3ET1
CL4
3.14
3.3
3.47
95
2.3
2.9
600
5
1
MMSZ3V6ET1
CL5
3.42
3.6
3.78
90
2.7
3.3
600
5
1
MMSZ3V9ET1
CL6
3.71
3.9
4.10
90
2.9
3.5
600
3
1
MMSZ4V3ET1
CL7
4.09
4.3
4.52
90
3.3
4.0
600
3
1
MMSZ4V7ET1
CL8
4.47
4.7
4.94
80
3.7
4.7
500
3
2
MMSZ5V1ET1
CL9
4.85
5.1
5.36
60
4.2
5.3
480
2
2
MMSZ5V6ET1
CM1
5.32
5.6
5.88
40
4.8
6.0
400
1
2
MMSZ6V2ET1
CM2
5.89
6.2
6.51
10
5.6
6.6
150
3
4
MMSZ6V8ET1
CM3
6.46
6.8
7.14
15
6.3
7.2
80
2
4
MMSZ7V5ET1
CM4
7.13
7.5
7.88
15
6.9
7.9
80
1
5
MMSZ8V2ET1
CM5
7.79
8.2
8.61
15
7.6
8.7
80
0.7
5
MMSZ9V1ET1
CM6
8.65
9.1
9.56
15
8.4
9.6
100
0.5
6
MMSZ10ET1
CM7
9.50
10
10.50
20
9.3
10.6
150
0.2
7
MMSZ11ET1
CM8
10.45
11
11.55
20
10.2
11.6
150
0.1
8
MMSZ12ET1
CM9
11.40
12
12.60
25
11.2
12.7
150
0.1
8
MMSZ13ET1
CN1
12.35
13
13.65
30
12.3
14.0
170
0.1
8
MMSZ15ET1
CN2
14.25
15
15.75
30
13.7
15.5
200
0.05
10.5
MMSZ16ET1
CN3
15.20
16
16.80
40
15.2
17.0
200
0.05
11.2
MMSZ18ET1
CN4
17.10
18
18.90
45
16.7
19.0
225
0.05
12.6
Devices listed in
bold, italic
are ON Semiconductor
Preferred
devices.
Preferred
devices are recommended choices for future use and
best overall value.
4. The type numbers shown have a standard tolerance of
±
5% on the nominal Zener Voltage.
5. Tolerance and Voltage Designation: Zener Voltage (VZ) is measured with the Zener Current applied for PW = 1 ms.
6. Z
ZT
and Z
ZK
are measured by dividing the AC voltage drop across the device by the AC current applied. The specified limits are for
I
Z(AC)
= 0.1 I
Z(DC),
with the AC frequency = 1 kHz.