4
DC/DC C
ONVERTERS
MHF+ SERIES
SINGLE AND DUAL
15 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODELS
MHF+2805D
MHF+2812D
MHF+2815D
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
OUTPUT VOLTAGE
+V
OUT
–V
OUT
4.95
5.00
5.05
11.88
12.00
12.12
14.85
15.00
15.15
VDC
4.92
5.00
5.08
11.82
12.00
1218
14.78
15.00
15.23
OUTPUT CURRENT
1
OUTPUT POWER
1
V
IN
= 16 to 40 VDC
V
IN
= 16 to 40 VDC
10 kHz - 2 MHz
Tc = –55°C to +125°C
—
±1.2
1.92
—
±0.625
1.125
—
±0.500
0.900
A
—
—
12
—
—
15
—
—
15
W
OUTPUT RIPPLE
VOLTAGE ±V
OUT
LINE REGULATION
—
—
30
60
80
120
—
—
30
60
80
120
—
—
30
50
80
120
mV p-p
BALANCED +V
OUT
LOAD
—
5
50
—
5
50
—
5
50
mV
Vin = 16 to 40 VDC
–V
OUT
—
—
80
—
—
100
—
—
100
LOAD REGULATION
BALANCED +V
OUT
LOAD
—
20
50
—
20
50
—
20
50
mV
–V
OUT
—
—
100
—
—
100
—
—
100
CROSS REGULATION
2
NEGATIVE V
OUT
CONTINUOUS
TRANSIENT 50 msec
NO LOAD
FULL LOAD
INHIBITED
10 kHz - 10 MHz
Tc = –55°C to +125°C
—
6
7.5
—
3
6
—
3
6
%
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
16
—
—
—
—
—
—
77
28
—
20
540
6
20
40
79
40
50
40
600
12
50
80
—
16
—
—
—
—
—
—
76
28
—
25
645
5
35
50
83
40
50
50
754
12
60
100
—
16
—
—
—
—
—
—
76
28
—
25
638
5
35
50
84
40
50
50
754
12
60
100
—
VDC
V
mA
INPUT RIPPLE
CURRENT
EFFICIENCY
mA p-p
%
LOAD FAULT
SHORT CIRCUIT
3
POWER DISSIPATION
RECOVERY
4
50% – 100% – 50%
TRANSIENT+V
OUT
—
—
3
6
30
—
—
3
6
50
—
—
3
6
W
ms
7.5
7.5
7.5
50
STEP LOAD RESP.
5
BALANCED LOADS
–600
200
600
–600
300
600
–600
300
600
mV pk
–V
OUT
–600
150
600
–600
100
500
–600
100
600
RECOVERY
4
16 – 40 – 40 VDC
TRANSIENT
6
RECOVERY
4
DELAY
OVERSHOOT
7
—
150
500
—
200
400
—
200
500
μs
STEP LINE RESP.
± V
OUT
–800
600
800
–750
550
750
–750
550
750
mV pk
—
—
0
0.8
12
100
1.2
20
250
—
—
0
0.8
12
200
1.2
25
750
—
—
0
0.8
12
200
1.2
25
750
ms
ms
START-UP
mV pk
Notes
1. Up to 13.5 watts, 90% (9.6W, 80% for 2805D) of the total output power is
available from either output providing the opposite output is simultaneously
carrying 10% (20% for 2805D) of the total output power. Each
output must carry a minimum of 10% (20% for 2805D) of the total output
power in order to maintain regulation on the negative output.
2. Effect on –Vout for the following conditions:
+Po = 50% to 10% and –Po = 50%
+Po = 50% and –Po = 50% to 10%
3. Indefinite short circuit protection not guaranteed above 125°C (case)
4. Recovery time is measured from application of the transient to point at
which Vout is within regulation.
5. Response of either output with the opposite output held at half of the total
output power.
6. Input step transition time >10 μs.
7. Input step transition time <100 μs.