8
MFC SERIES
UP TO 30 WATTS
FILTERED CONFIGURABLE DC/DC CONVERTERS
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODULES
05D
12D
15D
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
OUTPUT VOLTAGE
+VOUT
4.95
5.00
5.05
11.88
12.00
12.12
14.85
15.00
15.15
VDC
–VOUT
4.92
5.00
5.08
11.82
12.00
1218
14.78
15.00
15.23
OUTPUT CURRENT1
VIN = 16 to 40 VDC
—
±1.2
1.92
—
±0.625
1.125
—
±0.500
0.900
A
OUTPUT POWER1
VIN = 16 to 40 VDC
——
12
——
15
——
15
W
OUTPUT RIPPLE
10 kHz - 2 MHz
—
30
80
—
30
80
—
30
80
VOLTAGE ±VOUT
Tc = –55°C to +100°C
—
60
120
—
60
120
—
50
120
mV p-p
LINE REGULATION
BALANCED +VOUT
—
550
—
550
—
550
mV
Vin = 16 to 40 VDC
LOAD
–VOUT
——
80
——
100
——
100
LOAD REGULATION
BALANCED +VOUT
—
20
50
—
20
50
—
20
50
mV
LOAD
–VOUT
——
100
——
100
——
100
CROSS REGULATION2
NEGATIVE VOUT
—
6
7.5
—
36
—
36
%
INPUT VOLTAGE
CONTINUOUS
16
28
40
16
28
40
16
28
40
VDC
NO LOAD TO FULL
TRANSIENT 50 msec
——
50
——
50
——
50
V
INPUT CURRENT
NO LOAD
—
20
40
—
25
50
—
25
50
FULL LOAD
—
540
600
—
645
754
—
638
754
mA
INHIBITED
—
612
—
512
—
512
INPUT RIPPLE
10 kHz - 10 MHz
—
20
50
—
35
60
—
35
60
CURRENT
Tc = –55°C to +100°C
—
40
80
—
50
100
—
50
100
mA p-p
EFFICIENCY
77
79
—
76
83
—
76
84
—
%
LOAD FAULT
SHORT CIRCUIT3
POWER DISSIPATION
—
36
—
36
—
36
W
RECOVERY4
—
7.5
30
—
7.5
50
—
7.5
50
ms
STEP LOAD RESP.5
50% – 100% – 50%
TRANSIENT
+VOUT
–600
200
600
–600
300
600
–600
300
600
mV pk
–VOUT
–600
150
600
–600
100
500
–600
100
600
RECOVERY4
—
150
500
—
200
400
—
200
500
s
STEP LINE RESP.
16 – 40 – 40 VDC
±VOUT
TRANSIENT6
–800
600
800
–750
550
750
–750
550
750
mV pk
RECOVERY4
—
0.8
1.2
—
0.8
1.2
—
0.8
1.2
ms
START-UP
DELAY
—
12
20
—
12
25
—
12
25
ms
OVERSHOOT7
0
100
250
0
200
750
0
200
750
mV pk
Notes
1. Up to 13.5 watts, 90% (9.6W, 80% for 2805D) of the total output power is
available from either output providing the opposite output is simultaneously
carrying 10% (20% for 2805D) of the total output power. Each
output must carry a minimum of 10% (20% for 2805D) of the total output
power in order to maintain regulation on the negative outputs.
2. Effect on –Vout for the following conditions:
+Po = 50% to 10% and –Po = 50%
+Po = 50% and –Po = 50% to 10%
3. Indefinite short circuit protection not guaranteed above 100°C (case)
4. Recovery time is measured from application of the transient to point at
which Vout is within regulation.
5. Response of either output with the opposite output held at half of the total
output power.
6. Input step transition time >10s.
7. Input step transition time <100s.
15 Watt Dual Output Modules