MC74VHC4066
http://onsemi.com
3
DC ELECTRICAL CHARACTERISTIC Digital Section (Voltages Referenced to GND)
Symbol
Parameter
Test Conditions
VCC
V
Guaranteed Limit
Unit
– 55 to
25_C
v 85_C
v
125_C
VIH
Minimum HighLevel Voltage
ON/OFF Control Inputs
Ron = Per Spec
2.0
3.0
4.5
9.0
12.0
1.5
2.1
3.15
6.3
8.4
1.5
2.1
3.15
6.3
8.4
1.5
2.1
3.15
6.3
8.4
V
VIL
Maximum LowLevel Voltage
ON/OFF Control Inputs
Ron = Per Spec
2.0
3.0
4.5
9.0
12.0
0.5
0.9
1.35
2.7
3.6
0.5
0.9
1.35
2.7
3.6
0.5
0.9
1.35
2.7
3.6
V
Iin
Maximum Input Leakage
Current
ON/OFF Control Inputs
Vin = VCC or GND
12.0
± 0.1
± 1.0
± 1.0
μA
ICC
Maximum Quiescent Supply
Current (per Package)
Vin = VCC or GND
VIO = 0 V
6.0
12.0
2
4
20
40
40
160
μA
DC ELECTRICAL CHARACTERISTICS Analog Section (Voltages Referenced to GND)
Symbol
Parameter
Test Conditions
VCC
V
Guaranteed Limit
Unit
– 55 to
25_C
v 85_C
v
125_C
Ron
Maximum “ON” Resistance
Vin = VIH
VIS = VCC to GND
IS v 2.0 mA
2.0
3.0
4.5
9.0
12.0
—
120
70
—
160
85
—
200
100
Ω
Vin = VIH
VIS = VCC or GND (Endpoints)
IS v 2.0 mA
2.0
3.0
4.5
9.0
12.0
—
70
50
30
—
85
60
—
100
80
ΔRon
Maximum Difference in “ON”
Resistance Between Any Two
Channels in the Same Package
Vin = VIH
VIS = 1/2 (VCC GND)
IS v 2.0 mA
2.0
4.5
9.0
12.0
—
20
15
—
25
20
—
30
25
Ω
Ioff
Maximum OffChannel
Leakage
Current, Any One Channel
Vin = VIL
VIO = VCC or GND
Switch Off (Figure NO TAG)
12.0
0.1
0.5
1.0
μA
Ion
Maximum OnChannel
Leakage
Current, Any One Channel
Vin = VIH
VIS = VCC or GND
(Figure NO TAG)
12.0
0.1
0.5
1.0
μA
At supply voltage (VCC) approaching 3 V the analog switchon resistance becomes extremely nonlinear. Therefore, for lowvoltage
operation, it is recommended that these devices only be used to control digital signals.