MC100EP809
http://onsemi.com
4
Table 4. MAXIMUM RATINGS
Symbol
Parameter
Condition 1
Condition 2
Rating
Unit
VCC1
Core Power Supply
GND = 0 V
VCC0 = 1.6 to 2.0 V
4
V
VCC0
HSTL Output Power Supply
GND = 0 V
VCC1 = 3.0 to 3.6 V
4
V
VI
Input Voltage
GND = 0 V
VI v VCC1
4
V
Iout
Output Current
Continuous
Surge
50
100
mA
TA
Operating Temperature Range
0 to +85
°C
Tstg
Storage Temperature Range
65 to +150
°C
qJA
Thermal Resistance (JunctiontoAmbient)
0 lfpm
500 lfpm
LQFP32
80
55
°C/W
qJC
Thermal Resistance (JunctiontoCase)
Standard Board
LQFP32
12 to 17
°C/W
qJA
Thermal Resistance (JunctiontoAmbient)
0 lfpm
500 lfpm
QFN32
31
27
°C/W
qJC
Thermal Resistance (JunctiontoCase)
2S2P
QFN32
12
°C/W
Tsol
Wave Solder
Pb
PbFree
265
°C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 5. LVPECL DC CHARACTERISTICS VCCI = 3.0 V to 3.6 V; VCCO = 1.6 V to 2.0 V, GND = 0 V
Symbol
Characteristic
0°C
25°C
85°C
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
ICC
Core Power Supply Current
75
95
115
75
95
115
75
95
115
mA
VIH
Input HIGH Voltage (SingleEnded)
VCCI
1.165
VCCI
0.88
VCCI
1.165
VCCI
0.88
VCCI
1.165
VCCI
0.88
V
VIL
Input LOW Voltage (SingleEnded)
VCCI
1.945
VCCI
1.6
VCCI
1.945
VCCI
1.6
VCCI
1.945
VCCI
1.6
V
VIHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration)
LVPECL_CLK/LVPECL_CLK
1.2
VCCI
1.2
VCCI
1.2
VCCI
V
IIH
Input HIGH Current
150
mA
IIL
Input LOW Current
150
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. VIHCMR max varies 1:1 with VCCI. The VIHCMR range is referenced to the most positive side of the differential input signal.