M
Low-Cost, 2.7V to 5.5V, Analog Temperature
Sensor Switches in a SOT23
2
_______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
All voltages are referenced to GND.
V
CC
...........................................................................-0.3V to +6V
TOVER
,
TUNDER
(open drain)................................ -0.3V to +6V
TOVER, TUNDER (push-pull).................... -0.3V to (V
CC
+ 0.3V)
OUT, HYST.................................................-0.3V to (V
CC
+ 0.3V)
OUT Short to GND.........................................................Indefinite
ELECTRICAL CHARACTERISTICS
(V
CC
= 2.7V to 5.5V, R
PULLUP
= 100k
(open-drain output only), T
A
= -55
°
C to +125
°
C, unless otherwise noted. Typical values are at
T
A
= +25
°
C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Note 1:
100% production tested at T
A
= +25
°
C. Specifications over temperature are guaranteed by design.
Note 2:
The MAX6516
–
MAX6519 are available with internal factory-programmed temperature trip thresholds from -45
°
C to +115
°
C
in 10
°
C increments.
Note 3:
V
CC
must be greater than 4.5V for a switching threshold of -45
°
C.
Note 4:
Guaranteed by design.
Continuous Power Dissipation (T
A
= +70
°
C)
5-Pin SOT23 (derate 7.1mW/
°
C above +70
°
C)............571mW
Operating Temperature Range ........................-55
°
C to +125
°
C
Junction Temperature..................................................... +150
°
C
Storage Temperature Range.............................-65
°
C to +150
°
C
Lead Temperature (soldering, 10s)................................ +300
°
C
PARAMETER
SYMBOL
V
CC
CONDITIONS
MIN
2.7
TYP
MAX
5.5
UNITS
V
Supply Voltage Range
Hot-temperature thresholds
(+35
°
C to +115
°
C)
22
40
Supply Current
I
CC
Cold-temperature thresholds
(-45
°
C to +15
°
C)
40
μA
-15
°
C to +65
°
C
+75
°
C to +115
°
C
-45
°
C to -25
°
C (Note 3)
HYST = V
CC
HYST = GND
-1.5
-2.5
-3
+1.5
+2.5
+3
Temperature Threshold Accuracy
(Note 2)
T
TH
°
C
2
10
Temperature Threshold
Hysteresis
T
HYST
°
C
V
IH
V
IL
0.8 x V
CC
HYST Input Logic Level (Note 4)
0.2 x V
CC
V
I
SOURCE
= 500μA, V
CC
> 2.7V
I
SOURCE
= 800μA, V
CC
> 4.5V
I
SINK
= 1.2mA, V
CC
> 2.7V
I
SINK
= 3.2mA, V
CC
> 4.5V
0.8 x V
CC
V
CC
- 1.5
Logic Output Voltage High
(Push-Pull)
V
OH
V
0.3
0.4
Logic Output Voltage Low
(Push-Pull and Open Drain)
V
OL
V
Open-Drain Output Leakage
Current
OUT TEMPERATURE SENSITIVITY
Error to Equation:
OUT = 1.8015V - 10.62mV(T - 30)
- 1.1μV (T - 30)
2
Sensor Gain
OUT Capacitive Load (Note 4)
V
CC
= 2.7V, open-drain output = 5.5V
10
nA
-30
°
C to +125
°
C, V
CC
= 2.7V to 5.5V
-2
+2
-55
°
C to -30
°
C (Note 3)
-5
+2
°
C
-10.62
mV/
°
C
pF
1000
0.24
0 < I
OUT
< 40μA
-1μA < I
OUT
< 0
OUT Load Regulation
0.02
0.04
°
C
OUT Line Regulation
0.3
°
C/V