CONDITIONS
MAX336/MAX337
16-Channel/Dual 8-Channel,
Low-Leakage, CMOS Analog Multiplexers
4
_______________________________________________________________________________________
(Note 3)
pC
5.0
10
Q
Charge Injection
(Note 3)
ns
110
500
tOFF(EN)
Enable Turn-Off Time
(Note 3)
V
0
12
VNO,
VCOM
Analog Signal Range
ns
350
600
tON(EN)
Enable Turn-On Time
(Note 3)
ns
350
600
tTRANS
Transition Time (Note 3)
460
700
RON
On-Resistance
UNITS
MIN
TYP
MAX
(Note 2)
SYMBOL
PARAMETER
ELECTRICAL CHARACTERISTICS—Single Supply
(V+ = +12V, V- = 0V, GND = 0V, VAH = +2.4V, VAL = +0.8V, TA = TMIN to TMAX, unless otherwise noted.)
Note 2: The algebraic convention where the most negative value is a minimum and the most positive value a maximum is used in
this data sheet.
Note 3: Guaranteed by design.
Note 4:
RON = RON(MAX) - RON(MIN).
Note 5: Leakage parameters are 100% tested at the maximum rated hot temperature and guaranteed by correlation at TA = +25°C.
Note 6: Worst-case isolation is on channel 4 because of its proximity to the drain pin. Off isolation = 20log VCOM/VNO, where
VCOM = output and VNO = input to off switch.
INO = 0.2mA, VCOM = 3V or 10V, TA = +25°C
VNO_ = ±5V, VIN = 2.4V, Figure 1, TA = +25°C
VINH = 2.4V, VINL = 0V, VNO1 = 5V, Figure 3,
TA = +25°C
VINH = 2.4V, VINL = 0V, VNO1 = 5V, Figure 3,
TA = +25°C
CL = 100pF, VNO = 0V, RS = 0, TA = +25°C
SWITCH
DYNAMIC
-100
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
0.1
10
100
FREQUENCY RESPONSE
225
-225
-90
-45
0
45
-135
-180
90
135
180
MAX1336/337toc01
FREQUENCY (MHz)
LOSS
(dB)
PHASE
(DEGREES)
1
50
IN AND OUT
V+ = +15V
V- = -15V
ON PHASE
OFF LOSS
ON LOSS
100
0.001
10
10k
1k
100
100k
TOTAL HARMONIC DISTORTION
vs. FREQUENCY
0.01
MAX336/337
TOC02
FREQUENCY (Hz)
THD
(%)
1
0.1
10
V+ = +15V
V- = -15V
SIGNAL = 5Vp-p
600
IN AND OUT
100
10
1
0.1
0.01
0.0001
0.001
0.00001
MAX336/MAX337
TOC-03a
VIN (V)
3
0
6
9
12
15
SUPPLY CURRENT
vs. INPUT VOLTAGE
I+
(
A)
CURRENT SHOWN IS FOR DRIVING
ONE INPUT; TOTAL V+ CURRENT IS
MULTIPLIED BY NUMBER OF LOGIC
INPUTS DRIVEN
__________________________________________Typical Operating Characteristics
(TA = +25°C, unless otherwise noted.)