MAX14569
Dual-Pair LLT with Charge Pump
and High-ESD Protection
5
Note 2: VL must be less than or equal to VCC during normal operation. However, VL can be greater than VCC during startup and
shutdown conditions.
Note 3: All units are 100% production tested at TA = +25NC. Limits over the operating temperature range are guaranteed by design
and not production tested.
Note 4: Connect a 0.47F capacitor between CP1 and CP2.
Note 5: DIVBAT = [IVBAT(VENAB = VENCD = VIL) - IVBAT(VENAB = VENCD= 0V)]. Guaranteed by design and not production tested.
Note 6: VCC = 5.0V, VL = 1.6V to VCC, VBAT = 2.7V to 3.6V, VENAB = VENCD > VIH, RS = 50I, RL = 1MI, CL = 15pF, TA = -40NC to
+85NC, unless otherwise noted. Typical values are at VBAT = 3.6V, VL = 3.0V, and TA = +25NC.
ELECTRICAL CHARACTERISTICS (continued)
(VBAT = 2.3V to 5.5V, VL = 1.6V to 5.5V, CVBAT = 1FF, CVCC = 2.2FF, CVL = 0.1FF, TA = -40NC to +85NC, unless otherwise noted.
Typical values are at VBAT = 3.6V, VL = 3.0V, and TA = +25NC.) (Notes 2, 3, 4)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
CP_ Switching Frequency
fCP
No capacitor between CP1 and
CP2, 2.7V P VBAT P 4.5V
0.5
1
1.5
MHz
Efficiency
E
ICC = 10mA, VBAT = 2.7V,
VCC = 5.0V
90
%
THERMAL PROTECTION
Thermal Shutdown
TSHDN
+150
N
C
Thermal Hysteresis
THYST
+20
N
C
ESD PROTECTION
OUTAVCC, INBVCC,
OUTCVCC, INDVCC
Human Body Model
±25
kV
IEC 61000-4-2 Air Gap
Discharge
±15
IEC 61000-4-2 Contact
Discharge
±12
All Other Pins
Human Body Model
±2
kV