MITSUBISHI< LINEAR IC >
M52746SP
MITSUBISHI
BUS CONTROLLED 3CH VIDEO PRE-AMP FOR CRT DISPLAY MONITOR
25
Note13) Measure the amplitude output at OUT(24,28,31). The measured value is called
VOUT(24,28,31).
Sub contrast conrol characteristics VSC1 is calculated by the equation below:
VOUT
VSC1=20 LOG
Note14) Relative characteristics VSC1 is calculated by the equation below:
VSC1=VOUT(24)/VOUT(28) , VOUT(28)/VOUT(31) , VOUT(31)/VOUT(24)
Note15) Measuring condition and procedure are the same as described in Note13.
Note16) Measuring condition and procedure are the same as described in Note14.
Note17) Measuring condition and procedure are the same as described in Note13.
Note18) Measuring condition and procedure are the same as described in Note14.
Note19) Measure the amplitude output at OUT(24,28,31). The measured value is called
VOUT(24,28,31).
Main/Sub contrast conrol characteristics VMSC1 is calculated by the equation below:
VOUT
VMSC1=20 LOG
Note20) Relative characteristics VMSC1 is calculated by the equation below:
VMSC=VOUT(24)/VOUT(28) , VOUT(28)/VOUT(31) , VOUT(31)/VOUT(24)
Note21) Measure the amplitude output at OUT(24,28,31). The measured value is called
VOUT(24,28,31), and is ttreated as ABL1.
Note22) Relative characteristics ABL1 is calculated by the equation below:
ABL1=VOUT(24)/VOUT(28) , VOUT(28)/VOUT(31) , VOUT(31)/VOUT(24)
Note23) Measuring condition and procedure are the same as described in Note21.
Note24) Measuring condition and procedure are the same as described in Note22.
Note25) Measure the DC voltage at OUT(24,28,31) with a voltmeter. The measured value is called
VOUT(24,28,31), and is ttreated as VB1.
Note26) Relative characteristics VB1 is calculated by the difference in the output between the
channels.
VB1=VOUT(24)-VOUT(28) , VOUT(28)-VOUT(31) , VOUT(31)-VOUT(24)
Note27) Measuring condition and procedure are the same as described in Note25.
Note28) Measuring condition and procedure are the same as described in Note26.
Note29) Measuring condition and procedure are the same as described in Note25.
Note30) Measuring condition and procedure are the same as described in Note26.
12
0.7
(dB)
0.7
(dB)