Rev.1.10
Feb 13, 2006
page 20 of 44
REJ03B0180-0110
M35075-XXXFP
Fig. 12 Example of external clock input
Horizontal synchronous signal
External clock
Number of clock (N1)
1H
REGISTER SUPPLEMENTARY DESCRIPTION
(1) Setting external clock input and display frequency mode
Setting external clock input and display frequency mode (by
use of EXCK0, EXCK1 (12116), and DIV10 to DIV0 (12016) as
explained here following.
(a) When (EXCK1, EXCK0) = (0, 0) ......External clock mode 1
Fosc = 6.3 to 80 MHz (VDD = 4.75 to 5.25 V)
Fosc = 6.3 to 40 MHz (VDD = 2.50 to 3.50 V)
Input from the TCK pin a constant-period continuous
external clock that synchronizes with the horizontal
synchronous signal. And input from HOR pin a constant
period continuous horizontal synchronous signal.
Never stop inputting the clock while displaying.
Do not have to set a display frequency because the clock
just as it is entered from outside is used as the display
clock.
(b) When (EXCK1, EXCK0) = (0, 1) ......Internal clock mode
Fosc = 20 to 110 MHz (VDD = 4.75 to 5.25 V)
Clock input from the TCK pin is unnecessary. The multiply
clock of the internally generated horizontal synchronous
signal is used as the display clock.
The display frequency is set by setting the multiply value of
the horizontal synchronous frequency (of the display
frequency) in DIV10 to DIV0 (address 12016). Also, set the
display frequency range. (See the next page.)
Display frequency is calculated using the below expression.
Display frequency = Horizontal synchronous frequency x
Multiply value
10
Σ
n = 0
2nDIVn
(c) When (EXCK1, EXCK0) = (1, 0) ......… Setting disabled
(d) When (EXCK1, EXCK0) = (1, 1) ......External clock mode 2
Fosc = 20 to 110 MHz (VDD = 4.75 to 5.25 V)
Input from the TCK pin a constant-period continuous external
clock that synchronizes with the horizontal synchronous
signal. And input from HOR pin a constant-period continuous
horizontal synchronous signal.
Never stop inputting the clock while displaying.
An internal clock which is in sync with the external input clock
is used as the display clock.
Because the display frequency equals the external clock
frequency, set N1 (division value) that satisfies the below
expressions to DIV10 to DIV0 (address 12016) for make the
display frequency is equal to the external clock frequency.
N1 = external clock frequency / horizontal synchronous
frequency
N1 =
Also, set the display frequency range. (See the next page.)
相關(guān)PDF資料
PDF描述
M35076-001SP 24 X 12 CHARACTERS CRT CHAR DSPL CTLR, PDIP20
M35076-XXXSP 24 X 12 CHARACTERS CRT CHAR DSPL CTLR, PDIP20
M35076-XXXSP 24 X 12 CHARACTERS CRT CHAR DSPL CTLR, PDIP20
M35080FP 128 X 96 DOTS CRT CHAR OR GRPH DSPL CTLR, PDSO24
M37102E8-XXXFP 8-BIT, OTPROM, 4 MHz, MICROCONTROLLER, PQFP80
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
M35075-XXXFP 制造商:RENESAS 制造商全稱:Renesas Technology Corp 功能描述:SCREEN CHARACTER and PATTERN DISPLAY CONTROLLERS
M35076 制造商:RENESAS 制造商全稱:Renesas Technology Corp 功能描述:SCREEN CHARACTER and PATTERN DISPLAY CONTROLLERS
M35076-XXXSP 制造商:RENESAS 制造商全稱:Renesas Technology Corp 功能描述:SCREEN CHARACTER and PATTERN DISPLAY CONTROLLERS
M35080 制造商:STMICROELECTRONICS 制造商全稱:STMicroelectronics 功能描述:8 Kbit Serial SPI Bus EEPROM With Incremental Registers
M35080BN 制造商:STMICROELECTRONICS 制造商全稱:STMicroelectronics 功能描述:8 Kbit Serial SPI Bus EEPROM With Incremental Registers