11
11-9
32170/32174 Group User's Manual (Rev. 2.1)
Figure 11.1.6 Operation of A-D Conversion in Scan Mode (for 8-channel/16-channel Scan)
Note 1: A-D0 conversion start: Software trigger
→ Started by setting A-D0 conversion start bit to 1
_____
Hardware trigger
→ Started by output event bus 3 or ADTRG signal input
A-D1 conversion start: Software trigger
→ Started by setting A-D1 conversion start bit to 1
_____
Hardware trigger
→ Started by TID1 overflow/underflow or ADTRG signal input
Note 2: DMA transfer request: Can be generated for only the A-D0 converter.
A-D CONVERTERS
11.1 Outline of A-D Converters
ADiIN0
ADiDT0
ADiIN1
ADiIN2
ADiIN3
ADiDT1
ADiDT2
ADiDT3
ADiIN4
ADiDT4
ADiIN5
ADiIN6
ADiIN7
ADiDT5
ADiDT6
ADiDT7
ADiIN0
ADiDT0
ADiIN1
ADiIN2
ADiIN3
ADiDT1
ADiDT2
ADiDT3
ADiIN4
ADiDT4
ADiIN5
ADiIN6
ADiIN7
ADiDT5
ADiDT6
ADiDT7
ADiIN8
ADiDT8
ADiIN9
ADiIN10
ADiIN11
ADiDT9
ADiDT10
ADiDT11
ADiIN12
ADiDT12
ADiIN13
ADiIN14
ADiIN15
ADiDT13
ADiDT14
ADiDT15
i=0,1
Completed here when
operating in single-shot
scan mode
10-bit A-Di data register
During continuous scan mode
<8-channel scan>
A-D conversion interrupt request or DMA transfer request (Note 2)
Conversion
starts
(Note 1)
Completed here when
operating in single-shot
scan mode
10-bit A-Di data register
During continuous scan mode
<16-channel scan>
Conversion
starts
(Note 1)