Mitsubishi microcomputers
M16C / 62 Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Appendix Standard Serial I/O Mode (Flash Memory Version)
258
Figure 1.31.5. Timing for clearing the status register
Page Program Command
This command writes the specified page (256 bytes) in the flash memory sequentially one byte at a
time. Execute the page program command as explained here following.
(1) Send the
“
41
16
”
command code in the 1st byte of the transmission.
(2) Send addresses A
8
to A
15
and A
16
to A
23
in the 2nd and 3rd bytes of the transmission respectively.
(3) From the 4th byte onward, as write data (D
0
–
D
7
) for the page (256 bytes) specified with addresses
A
8
to A
23
is input sequentially from the smallest address first, that page is automatically written.
When reception setup for the next 256 bytes ends, the RTS1 (BUSY) signal changes from the
“
H
”
to
the
“
L
”
level. The result of the page program can be known by reading the status register. For more
information, see the section on the status register.
Each block can be write-protected with the lock bit. For more information, see the section on the data
protection function. Additional writing is not allowed with already programmed pages.
CLK1
RxD1
TxD1
RTS1(BUSY)
50
16
(M16C reception data)
(M16C transmit data)
Clear Status Register Command
This command clears the bits (SR3
–
SR5) which are set when the status register operation ends in
error. When the
“
50
16
”
command code is sent in the 1st byte of the transmission, the aforementioned
bits are cleared. When the clear status register operation ends, the RTS1 (BUSY) signal changes
from the
“
H
”
to the
“
L
”
level.
CLK1
RxD1
TxD1
RTS1(BUSY)
A
8
to
A
15
A
16
to
A
23
41
16
data0
data255
(M16C reception data)
(M16C transmit data)
Figure 1.31.6. Timing for the page program