1-161
Under
Specifications in this manual are tentative and subject to change
Rev. G
A-D Converter
MITSUBISHI MICROCOMPUTERS
M30222 Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
(1) One-shot mode
In one-shot mode, the pin selected using the analog input pin select bit is used for one-shot A-D
conversion. Table 1.50 shows the specifications of one-shot mode. Figure 1.129 shows the A-D con-
trol register in one-shot mode.
Table 1.50. One-shot mode specifications
Figure 1.129. A-D conversion register in one-shot mode
A-D control register 0 (Note 1)
Symbol
ADCON0
Address
03D6
16
When reset
00000XXX
2
b7
b6
b5
b4
0
b3
0
b2
b1
b0
Analog input pin select
bit
Bit symbol
Bit name
Function
CH1
CH2
A-D operation mode
select bit 0
Trigger select bit
MD0
MD1
0 : Software trigger
1 : AD
TRG
trigger
0 : A-D conversion disabled
1 : A-D conversion started
0: f
AD
/4 is selected
1: f
AD
/2 is selected
TRG
ADST
A-D conversion start flag
Frequency select bit 0
CKS0
W
R
A-D control register 1 (Note)
Symbol
ADCON1
Address
03D7
16
When reset
00
16
Bit name
Function
Bit symbol
b7
b6
b5
1
b4
b3
b2
0
b1
b0
A-D sweep pin
select bit
SCAN0
SCAN1
MD2
BITS
8/10-bit mode select bit
0 : 8-bit mode
1 : 10-bit mode
VCUT
OPA0
Vref connect bit
OPA1
A-D operation mode
select bit 1
0 : Any mode other than repeat sweep
mode 1
1 : Vref connected
External op-amp
connection mode bit
0 0 : ANEX0 and ANEX1 are not used
W
R
Invalid in one-shot mode
0 0 0 : AN
0
is selected
1
0 0 1 : AN
2
is selected
0 1 1 : AN
3
is selected
1 0 0 : AN
4
is selected
1 0 1 : AN
5
is selected
1 1 0 : AN
6
is selected
1 1 1 : AN
7
is selected
(Note 2)
b2 b1 b0
(Note 2)
b4 b3
CH0
b7 b6
Note 1: If the A-D control register is rewritten during A-D conversion, the conversion
result is indeterminate.
Note 2: When changing A-D operation mode, set analog input pin again.
Frequency select bit1
AD
/is selected
AD
/4 is selected
0 : f
AD
CKS1
Note: If the A-D control register is rewritten during A-D conversion, the conversion
result is indeterminate.
Item
Specification
Function
The pin selected by the analog input pin select bit is used for one-shot A-D conversion
Start condition
Writing 1 to A-D conversion start flag
Stop condition
Writing 0 to A-D conversion start flag
End of A-D conversion (A-D conversion start flag changes ot 0 , except when exter-
nal trigger is selected).
Interrupt request
generation timing
End of A-D conversion
Input pin
One of AN
0
to AN
7
as selected
Reading A-D
converter results
Read A-D register corresponding to selected pin