3
LY
LY
Coil inductance
(ref. value) (H)
Armature
OFF
0.04
0.17
0.69
3.22
14.54
19.20
54.75
83.50
Coil
resistance
(
)
12.20
46
180
788
3,750
4,430
12,950
18,790
Pick-up
voltage
(% of rated voltage)
80% max.
Dropout
voltage
Maximum
voltage
Power
consumption
(VA, W)
Rated
voltage (V)
Rated current (mA)
Armature
ON
0.08
0.33
1.30
5.66
24.60
32.10
94.07
136.40
50 Hz
214.10
106.50
53.80
25.70
11.70/12.90
9.90/10.80
6.20/6.80
4.80/5.30
60 Hz
183
91
46
22
10/11
8.40/9.20
5.30/5.80
4.20/4.60
6
12
24
50
100/110
110/120
200/220
220/240
30% min.
110%
Approx.
1.00 to 1.20
(60 Hz)
Approx.
0.90 to 1.10
(60 Hz)
Specifications
I
CONTACT DATA
Single contact
SPDT
Resistive load
(p.f. = 1)
Bifurcated contact
DPDT
Resistive load
(p.f. = 1)
DPDT, 3PDT, 4PDT
Resistive load
(p.f. = 1)
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
10 A at 110 VAC
7 A at 24 VDC
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
7.5 A at 110 VAC
5 A at 24 VDC
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
4 A at 110 VAC
4 A at 24 VDC
Load
Rated load
15 A at 110 VAC
15 A at 24 VDC
AgCdO
15 A
250 VAC
125 VDC
15 A
10 A at 110 VAC
10 A at 24 VDC
5 A at 110 VAC
5 A at 24 VDC
Contact material
Carry current
Max. operating
voltage
Max. operating
current
Max. switching
capacity
Min. permissible
load
10 A
7 A
10 A
7 A
1,700 VA
360 W
100 mA, 5 VDC
1,100 VA
170 W
1,100 VA
240 W
830 VA
120 W
550 VA
120 W
10 mA, 5 VDC
440 VA
100 W
I
COIL DATA
1- and 2-pole types – AC
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
°
C (73
°
F) with tolerances of +15%, -20% for
AC rated current, and
±
15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23
°
C (73
°
F).
4. Class B coil insulation is available.
Coil inductance
(ref. value) (H)
Armature
OFF
0.16
0.73
3.20
10.60
45.60
Coil
resistance
(
)
Pick-up
voltage
(% of rated voltage)
80% max.
Dropout
voltage
Maximum
voltage
Power
consumption
(VA, W)
Rated
voltage (V)
Armature
ON
0.33
1.37
5.72
21
86.20
Rated current (mA)
6
12
24
48
100/110
150
75
36.90
18.50
9.10/10
40
160
650
2,600
11,000
10% min.
110%
Approx.
0.90
1- and 2-pole types – DC