4
LT1395/LT1396/LT1397
SYMBOL
t
ON
t
OFF
–3dB BW
PARAMETER
Turn-On Delay Time (Note 9)
Turn-Off Delay Time (Note 9)
–3dB Bandwidth
CONDITIONS
R
F
= R
G
= 255
, R
L
= 100
, (LT1395CS6 only)
R
F
= R
G
= 255
, R
L
= 100
, (LT1395CS6 only)
A
V
= 1, R
F
= 374
, R
L
= 100
A
V
= 2, R
F
= R
G
= 255
, R
L
= 100
A
V
= 1, R
F
= 374
, R
L
= 100
A
V
= 2, R
F
= R
G
= 255
, R
L
= 100
R
F
= R
G
= 255
, R
L
= 100
, V
OUT
= 1V
P-P
R
F
= R
G
= 255
, R
L
= 100
, V
OUT
= 1V
P-P
R
F
= R
G
= 255
, R
L
= 100
, V
OUT
= 1V
P-P
0.1%, A
V
= –1, R
F
= R
G
= 280
, R
L
= 150
R
F
= R
G
= 255
, R
L
= 150
R
F
= R
G
= 255
, R
L
= 150
MIN
TYP
30
40
400
350
100
100
1.3
2.5
10
25
0.02
0.04
MAX
75
100
UNITS
ELECTRICAL C
The
G
denotes specifications which apply over the specified operating temperature range, otherwise specifications are at T
A
= 25
°
C.
For each amplifier: V
CM
= 0V, V
S
=
±
5V, pulse tested, unless otherwise noted. (Note 5)
HARA TERISTICS
Note 1:
Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2:
This parameter is guaranteed to meet specified performance
through design and characterization. It has not been tested.
Note 3:
A heat sink may be required depending on the power supply
voltage and how many amplifiers have their outputs short circuited.
Note 4:
The LT1395C/LT1396C/LT1397C are guaranteed functional over
the operating temperature range of –40
°
C to 85
°
C.
Note 5:
The LT1395C/LT1396C/LT1397C are guaranteed to meet specified
performance from 0
°
C to 70
°
C. The LT1395C/LT1396C/LT1397C are
designed, characterized and expected to meet specified performance from
–40
°
C and 85
°
C but is not tested or QA sampled at these temperatures.
For guaranteed I-grade parts, consult the factory.
Note 6:
T
J
is calculated from the ambient temperature T
A
and the
power dissipation P
D
according to the following formula:
LT1395CS5: T
J
= T
A
+ (P
D
250
°
C/W)
LT1396CS6: T
J
= T
A
+ (P
D
230
°
C/W)
LT1395CS8: T
J
= T
A
+ (P
D
150
°
C/W)
LT1396CS8: T
J
= T
A
+ (P
D
150
°
C/W)
LT1396CMS8: T
J
= T
A
+ (P
D
250
°
C/W)
LT1397CS14: T
J
A
+ (P
D
100
°
C/W)
LT1397CGN16: T
J
= T
A
+ (P
D
135
°
C/W)
Note 7:
Slew rate is measured at
±
2V on a
±
3V output signal.
Note 8:
Differential gain and phase are measured using a Tektronix
TSG120YC/NTSC signal generator and a Tektronix 1780R Video
Measurement Set. The resolution of this equipment is 0.1% and 0.1
°
.
Ten identical amplifier stages were cascaded giving an effective
resolution of 0.01% and 0.01
°
.
Note 9:
For LT1395CS6, turn-on delay time (t
ON
) is measured from
control input to appearance of 1V(50%) at the output, for V
IN
= 1V and
A
V
= 2. Likewise, turn-off delay time (t
OFF
) is measured from control
input to appearance of 1V(50%) on the output for V
IN
= 1V and
A
V
= 2. This specification is guaranteed by design and characterization.
SMALL SIGNAL
–3dB BW (MHz)
400
350
350
SMALL SIGNAL
0.1dB BW (MHz)
100
100
100
SMALL SIGNAL
PEAKING (dB)
0.1
0.1
0.1
V
S
(V)
±
5
±
5
±
5
A
V
1
2
–1
R
L
(
)
100
100
100
R
F
(
)
374
255
280
R
G
(
)
–
255
280
TYPICAL AC PERFOW U
ns
ns
MHz
MHz
MHz
MHz
ns
ns
0.1dB BW
0.1dB Bandwidth
t
r
, t
f
t
PD
os
t
S
dG
dP
Small-Signal Rise and Fall Time
Propagation Delay
Small-Signal Overshoot
Settling Time
Differential Gain (Note 8)
Differential Phase (Note 8)
%
ns
%
DEG