參數(shù)資料
      型號: LS4001-9EPD1B1
      廠商: POWER-ONE INC
      元件分類: 電源模塊
      英文描述: 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      封裝: METAL, CASE S02, MODULE
      文件頁數(shù): 14/27頁
      文件大?。?/td> 599K
      代理商: LS4001-9EPD1B1
      100 Watt AC-DC Converters
      S Series PFC
      Edition 01/01.2001
      21/27
      P Potentiometer
      The potentiometer provides an output voltage adjustment
      range of +10/–60% of
      Uo nom and is accessible through a
      hole in the front cover. This feature enables compensation
      for voltage drops across the connector and wiring. Option P
      is not recommended if units are connected in parallel.
      Option P excludes the R-function. With double output units
      both outputs are affected by the potentiometer setting (dou-
      bling the voltage setting if the outputs are in series).
      If the output voltages are increased above
      Uo nom via R-in-
      put control, option P setting, remote sensing or option T, the
      output current(s) should be reduced accordingly so that
      Po nom is not exceeded.
      -9 Extended Temperature Range
      Option –9 extends the operational ambient temperature
      range from –25...71
      °C (standard) to –40...71°C. The power
      supplies provide full nominal output power with convection
      cooling. Option -9 excludes inrush current limitation by
      NTC.
      Description of Options
      Table 16: Survey of options
      Option
      Function of option
      Characteristic
      –9
      Extended operational ambient temperature range
      TA = –40...71°C
      E
      Electronic inrush current limitation circuitry
      Active inrush current limitation
      P 1
      Potentiometer for fine adjustment of output voltage
      Adjustment range +10/-60% of
      Uo nom, excludes R input
      D 2
      Input and/or output undervoltage monitoring circuitry
      Safe data signal output (D0...DD)
      V 2 3
      Input and/or output undervoltage monitoring circuitry
      ACFAIL signal according to VME specifications (V0, V2, V3)
      T
      Current sharing
      Interconnect T-pins if paralleling outputs (5 units max.)
      B1, B2
      Cooling plate
      Replaces standard heat sink, allowing direct chassis-mounting
      1 Function R excludes option P and vice versa
      2 Option D excludes option V and vice versa
      3 Only available if main output voltage Uo1 = 5.1 V
      Table 14: Leakage currents
      Characteristic
      Class I
      Unit
      LS 4000...LS 5000
      Maximum earth
      Permissible according to IEC/EN 60950
      3.5
      mA
      leakage current
      Specified value at 254 V, 50 Hz
      0.82
      Safety of operator accessible output circuit
      If the output circuit of an AC-DC converter is operator ac-
      cessible, it shall be an SELV circuit according to the IEC/EN
      60950 related safety standards.
      The following table shows a possible installation configura-
      tion, compliance with which causes the output circuit of an
      S series AC-DC converter to be an SELV circuit according
      to IEC/EN 60950 up to a configured output voltage (sum of
      nominal voltages if in series or +/– configuration) of 36 V.
      However, it is the sole responsibility of the installer to as-
      sure the compliance with the relevant and applicable safety
      regulations. More information is given in:
      Technical Infor-
      mation: Safety.
      Table 15: Safety concept leading to an SELV output circuit
      Conditions
      AC-DC converter
      Installation
      Result
      Nominal voltage
      Grade of insulation
      Measures to achieve the resulting
      Safety status of the AC-DC
      between input and output
      safety status of the output circuit
      converter output circuit
      provided by the AC-DC converter
      Mains
      Double or reinforced
      Earthed case 1 and installation
      SELV circuit
      ≤250 V AC
      according to the applicable standards
      1 The earth connection has to be provided by the installer according to the relevant safety standards, e.g. IEC/EN 60950.
      AC-DC
      con-
      verter
      Mains
      SELV
      Earth connection
      +
      ~
      10021
      Fuse
      Fig. 30
      Schematic safety concept. Use fuses and earth connec-
      tion as per Installation Instructions and table Safety con-
      cept leading to an SELV output circuit.
      相關(guān)PDF資料
      PDF描述
      LS4001-9EPTB2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS4301-7EPD2TB2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS4301-7ERD5TB2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS4301-7ERD8B2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS4301-7PD0B2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      相關(guān)代理商/技術(shù)參數(shù)
      參數(shù)描述
      LS4001-9ER 制造商:Power-One 功能描述:ACDC - Bulk
      LS40077-003 制造商:MASTER.SPEC. 功能描述:LS40077-003 制造商:MASTER/- 功能描述:LS40077-003
      LS-400A 功能描述:十進(jìn)盒 Inductance RoHS:否 制造商:IET Labs 產(chǎn)品:Decade Resistance Boxes 電阻范圍:0 Ohms to 9999999 Ohms 準(zhǔn)確性:+/- 1 %
      LS-400L 制造商:IET Labs Inc 功能描述:LOW INDUCTANCE SUBSTITUTER
      LS-401 制造商:PANASONIC INDUSTRIAL AUTOMATION SALES 功能描述:LASER SENSOR NPN QD