      Cassette Style
      100 Watt AC-DC Converters
      S Series PFC
      Edition 01/01.2001
      20/27
      Table 13: Isolation
      Characteristic
      Input to
      Output to Output to
      Unit
      case
      output
      case
      output
      Electric
      Required according to
      1.5
      3.0 1
      ––
      kVrms
      strength
      IEC/EN 60950
      2.1
      4.2 1
      ––
      kV DC
      test voltage
      Actual factory test 1 s
      2.8
      5.6 1
      1.4
      0.14
      AC test voltage equivalent
      2.0
      4.0 1
      1.0
      0.1
      kVrms
      to actual factory test
      Insulation resistance at 500 V DC
      >300
      >100 2
      M
      1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.
      2 Tested at 100 V DC.
      For creepage distances and clearances refer to:
      Technical Information: Safety.
      Leakage Currents in AC-DC operation
      Leakage currents flow due to internal leakage capacitance
      and RFI suppression Y-capacitors. The current values are
      proportional to the mains voltage and nearly proportional to
      the mains frequency and are specified at an input voltage of
      254 V (50 Hz) where phase, neutral and protective earth
      are correctly connected as required for class I equipment.
      V
      MI
      500
      1500
      10 k
      220 nF
      22 nF
      10061
      Under test conditions the leakage current flows through a
      measuring instrument (MI) as described in fig.:
      Measuring
      instrument for earth leakage current tests, which takes into
      account impedance and sensitivity of a person touching
      unearthed accessible parts. The current value is calculated
      by dividing the measured voltage by 500
      . If inputs of S-
      units are connected in parallel, their individual leakage cur-
      rents are added.
      Fig. 28
      Measuring instrument (MI) for earth leaking current tests
      according to IEC/EN 60950.
      Vo+
      Vo–
      N
      P
      10062
      N
      P
      MI for
      earth
      leakage
      current
      Fig. 29
      Test set-up
      Standards and Approvals
      All AC-DC converters correspond to class I equipment.
      They are UL recognized according to UL 1950, UL recog-
      nized for Canada to CAN/CSA C22.2 No. 950-95 and LGA
      approved to IEC/EN 60950 standards.
      The units have been evaluated for:
      Building in
      Basic insulation between input and case, based on 250 V
      AC and 400 V DC
      Double or reinforced insulation between input and output,
      based on 250 V AC and 400 V DC
      Basic insulation between output and case based on
      200 V AC and DC
      Operational insulation between output and output
      Connecting the input to a primary or secondary circuit
      which is subject to a maximum transient rating of 2500 V
      (overvoltage category III based on a 110 V primary cir-
      cuit, overvoltage category II based on a 230 V primary
      circuit).
      The use in a pollution degree 2 environment
      The UL 1950 recognition limits the minimum input voltage
      to
      Ui = Ui min + 5 V AC = 90 V AC if the case temperature
      exceeds 90
      °C.
      The AC-DC converters are subject to manufacturing sur-
      veillance in accordance with the above mentioned UL,
      CSA, EN and with ISO 9001 standards.
      Isolation
      The electric strength test is performed as factory test in ac-
      cordance with IEC/EN 60950 and UL 1950 and should not
      be repeated in the field. Power-One will not honour any
      guarantee claims resulting from electric strength field tests.
      Important: Testing by applying AC voltages will result in
      high and dangerous leakage currents flowing through
      the Y-capacitors (see fig.:
      Block diagram).
      相關(guān)PDF資料
      PDF描述
      LS4001-7PD5B1 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS4001-7RD1TB2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS4001-9EPD4 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS4001-9EPD5TB2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS4001-9EPD8TB2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      相關(guān)代理商/技術(shù)參數(shù)
      參數(shù)描述
      LS4001-7R 功能描述:線(xiàn)性和開(kāi)關(guān)式電源 Euro-Cassette 100W (5.1V) RoHS:否 制造商:TDK-Lambda 產(chǎn)品:Switching Supplies 開(kāi)放式框架/封閉式:Enclosed 輸出功率額定值:800 W 輸入電壓:85 VAC to 265 VAC 輸出端數(shù)量:1 輸出電壓(通道 1):20 V 輸出電流(通道 1):40 A 商用/醫(yī)用: 輸出電壓(通道 2): 輸出電流(通道 2): 安裝風(fēng)格:Rack 長(zhǎng)度: 寬度: 高度:
      LS4001-9ER 制造商:Power-One 功能描述:ACDC - Bulk
      LS40077-003 制造商:MASTER.SPEC. 功能描述:LS40077-003 制造商:MASTER/- 功能描述:LS40077-003
      LS-400A 功能描述:十進(jìn)盒 Inductance RoHS:否 制造商:IET Labs 產(chǎn)品:Decade Resistance Boxes 電阻范圍:0 Ohms to 9999999 Ohms 準(zhǔn)確性:+/- 1 %
      LS-400L 制造商:IET Labs Inc 功能描述:LOW INDUCTANCE SUBSTITUTER