SMSC DS – LPC47M192 
Page 95 
Rev. 03/30/05 
DATASHEET 
Table 44B  
Table 44C 
CONFIG REG B 
BITS 2:0 
IRQ SELECTED 
CONFIG REG B
BITS 5:3 
DMA 
SELECTED 
3 
2 
1 
All Others 
15 
14 
11 
10 
9 
7 
5 
110 
101 
100 
011 
010 
001 
111 
000 
011 
010 
001 
000 
All Others 
OPERATION 
Mode Switching/Software Control 
Software will execute P1284 negotiation and all operation prior to a data transfer phase under programmed I/O 
control (mode 000 or 001). Hardware provides an automatic control line handshake, moving data between the FIFO 
and the ECP port only in the data transfer phase (modes 011 or 010). 
Setting the mode to 011 or 010 will cause the hardware to initiate data transfer. 
If the port is in mode 000 or 001 it may switch to any other mode.  If the port is not in mode 000 or 001 it can only be 
switched into mode 000 or 001.  The direction can only be changed in mode 001. 
Once in an extended forward mode the software should wait for the FIFO to be empty before switching back to mode 
000 or 001.  In this case all control signals will be deasserted before the mode switch. In an ecp reverse mode the 
software waits for all the data to be read from the FIFO before changing back to mode 000 or 001.  Since the 
automatic hardware  ecp  reverse handshake only cares about the state of the FIFO it may have acquired extra data 
which will be discarded. It may in fact be in the middle of a transfer when the mode is changed back to 000 or 001. In 
this case the port will deassert nAutoFd independent of the state of the transfer. The design shall not cause glitches 
on the handshake signals if the software meets the constraints above. 
ECP Operation 
Prior to ECP operation the Host must negotiate on the parallel port to determine if the peripheral  supports   the  ECP 
protocol. This is a somewhat complex negotiation carried out under program control in mode 000. 
After negotiation, it is necessary to initialize some of the port bits. The following are required: 
Set  Direction  = 0, enabling the drivers. 
Set  strobe  = 0, causing the nStrobe signal to default to the deasserted state. 
Set  autoFd  = 0, causing the nAutoFd signal to default to the deasserted state.  
Set  mode  = 011  (ECP Mode)  
ECP address/RLE bytes or data bytes may be sent automatically by writing the ecpAFifo or ecpDFifo respectively. 
Note that all FIFO data transfers are byte wide and byte aligned.  Address/RLE transfers are byte-wide and only 
allowed in the forward direction. 
The host may switch directions by first switching to mode = 001, negotiating for the forward or reverse channel, 
setting direction to 1 or 0, then setting mode = 011. When direction is 1 the hardware shall handshake for each ECP 
read data byte and attempt to fill the FIFO.  Bytes may then be read from the ecpDFifo as long as it is not empty. 
ECP transfers may also be accomplished (albeit slowly) by handshaking individual bytes under program control in 
mode = 001, or 000. 
Termination from ECP Mode 
Termination from ECP Mode is similar to the termination from Nibble/Byte Modes. The host is permitted to terminate 
from ECP Mode only in specific well-defined states. The termination can only be executed while the bus is in the