SMSC DS – LPC47M14X 
Page 52 
Rev. 03/19/2001 
Read A Track
This command is similar to the Read Data command except that the entire data field is read continuously from each of 
the sectors of a track.  Immediately after encountering a pulse on the nINDEX pin, the FDC starts to read all data fields 
on the track as continuous blocks of data without regard to logical sector numbers. If the FDC finds an error in the ID or 
DATA CRC check bytes, it continues to read data from the track and sets the appropriate error bits at the end of the 
command.  The FDC compares the ID information read from each sector with the specified value in the command and 
sets the ND flag of Status Register 1 to a “1” if there no comparison.  Multi-track or skip operations are not allowed with 
this command. The MT and SK bits (bits D7 and D5 of the first command byte respectively) should always be set to "0". 
This command terminates when the EOT specified number of sectors has not been read. If the FDC does not find an ID 
Address Mark on the diskette after the second occurrence of a pulse on the INDEX pin, then it sets the IC code in Status 
Register 0 to "01" (abnormal termination), sets the MA bit in Status Register 1 to "1", and terminates the command.
Table 23  –  Result Phase Table 
MT
HEAD
FINAL SECTOR 
TRANSFERRED TO
HOST
ID INFORMATION AT RESULT PHASE
C
H
R
N
0 
0 
Less than EOT 
NC 
NC 
R + 1 
NC 
Equal to EOT 
C + 1 
NC 
01 
NC 
1 
Less than EOT 
NC 
NC 
R + 1 
NC 
Equal to EOT 
C + 1 
NC 
01 
NC 
1 
0 
Less than EOT 
NC 
NC 
R + 1 
NC 
Equal to EOT 
NC 
LSB 
01 
NC 
1 
Less than EOT 
Equal to EOT 
NC 
C + 1 
NC 
LSB 
R + 1 
01 
NC 
NC 
NC:
  No Change, the same value as the one at the beginning of command execution. 
LSB:
  Least Significant Bit, the LSB of H is complemented.
Write Data 
After the Write Data command has been issued, the FDC loads the head (if it is in the unloaded state), waits the 
specified head load time if unloaded (defined in the Specify command), and begins reading ID fields. When the sector 
address read from the diskette matches the sector address specified in the command, the FDC reads the data from the 
host via the FIFO and writes it to the sector's data field. 
After writing data into the current sector, the FDC computes the CRC value and writes it into the CRC field at the end of 
the sector transfer. The Sector Number stored in "R" is incremented by one, and the FDC continues writing to the next 
data field.  The FDC continues this "Multi-Sector Write Operation". Upon receipt of a terminal count signal or if a FIFO 
over/under run occurs while a data field is being written, then the remainder of the data field is filled with zeros.   The 
FDC reads the ID field of each sector and checks the CRC bytes. If it detects a CRC error in one of the ID fields, it sets 
the IC code in Status Register 0 to "01" (abnormal termination), sets the DE bit of Status Register 1 to "1", and 
terminates the Write Data command. 
The Write Data command operates in much the same manner as the Read Data command. The following items are the 
same. Please refer to the Read Data Command for details: 
 
Transfer Capacity 
 
EN (End of Cylinder) bit 
 
ND (No Data) bit 
 
Head Load, Unload Time Interval 
 
ID information when the host terminates the command 
Definition of DTL when N = 0 and when N does not = 0 
Write Deleted Data
This command is almost the same as the Write Data command except that a Deleted Data Address Mark is written at 
the beginning of the Data Field instead of the normal Data Address Mark.  This command is typically used to mark a bad 
sector containing an error on the floppy disk.