LM124A RAD HARD — DC Drift Values
(Note 10)
(The following conditions apply to all the following parameters, unless otherwise specified.)
DC: "Delta calculationsperformed
on QMLV devices at group B, subgroup 5 only"
SYMBOL
PARAMETER
CONDITIONS
NOTES
MIN
MAX
UNIT
SUB-
GROUPS
1
Vio
Input Offset Voltage
Vcc+ = 30V, Vcc- = Gnd,
Vcm = -15V
Vcc+ = 30V, Vcc- = Gnd,
Vcm = -15V
-0.5
0.5
mV
±
Iib
Input Bias Current
-10
10
nA
1
Electrical Characteristics — POST RADIATION LIMITS +25C
(Note 10)
(The following conditions apply to all the following parameters, unless otherwise specified.)
All voltages referenced to device
ground.
SYMBOL
PARAMETER
CONDITIONS
NOTES
MIN
MAX
UNIT
SUB-
GROUPS
1
Vio
Input Offset Voltage
Vcc+ = 30V, Vcc- = Gnd,
Vcm = -15V
Vcc+ = 2V, Vcc- = -28V,
Vcm = 13V
Vcc+ = 5V, Vcc- = GND,
Vcm = -1.4V
Vcc+ = 2.5V, Vcc- = -2.5,
Vcm = 1.1V
Vcc+ = 30V, Vcc- = GND,
Vcm = -15V
Vcc+ = 2V, Vcc- = -28V,
Vcm = 13V
Vcc+ = 5V, Vcc- = GND,
Vcm = -1.4V
Vcc+ = 2.5V, Vcc- = -2.5V,
Vcm = 1.1V
Vcc+ = 30V, Vcc- = GND,
Vcm = -15V
Vcc+ = 2V, Vcc- = -28V,
Vcm = 13V
Vcc+ = 5V, Vcc- = GND,
Vcm = -1.4V
Vcc+ = 2.5V, Vcc- = -2.5V,
Vcm = 1.1V
Vcc+ = 30V, Vcc- = GND,
1V
≤
Vo
≤
26V, Rl = 10K Ohms
Vcc+ = 30V, Vcc- = GND,
5V
≤
Vo
≤
20V, Rl = 2K Ohms
(Note 10)
-2.5
2.5
mV
(Note 10)
-2.5
2.5
mV
1
(Note 10)
-2.5
2.5
mV
1
(Note 10)
-2.5
2.5
mV
1
Iio
Input Offset Current
(Note 10)
-15
15
nA
1
(Note 10)
-15
15
nA
1
(Note 10)
-15
15
nA
1
(Note 10)
-15
15
nA
1
±
Iib
Input Bias Current
(Note 10)
-75
+0.1
nA
1
(Note 10)
-75
+0.1
nA
1
(Note 10)
-75
+0.1
nA
1
(Note 10)
-75
+0.1
nA
1
Avs+
Voltage Gain
(Note 10)
40
V/mV
4
(Note 10)
40
V/mV
4
Note 6:
Guaranteed by Vio tests.
Note 7:
Datalog reading in K=V/mV
Note 8:
Guaranteed, not tested
Note 9:
Calculated parameters
Note 10:
Pre and post irradiation limits are identical to those listed under AC and DC electrical characteristics except as listed in the Post Radiation Limits Table.
These parts may be dose rate sensitive in a space environment and demonstrate enhanced low dose rate effect. Radiation end point limits for the noted parameters
are guaranteed only for the conditions as specified in MIL-STD-883, Method 1019