electrical characteristics at specified free-air temperature, Vcc = 5 V (unless otherwise noted)
PARAMETER 
TEST CONDITIONS* 
LM358 
UNIT
MIN
TYP
3 
MAX
7 
9
V
IO 
Input offset voltage
Vcc = 5 V to MAX, 
V
IC
 = V
ICR 
min,
Vo=1.4 V
25 
°
C 
Full range
mV
α
V
IO
Average temperature coefficient
of input offset voltage
l
IO 
Input offset current
α
lIO
Average temperature coefficient
of input offset current
I
IB 
Input bias current
V
ICR 
Common-mode input voltage
range
V
OH 
High-level output voltage
Full range
7
μ
V/
°
C
Vo=1.4 V 
25 
°
C 
Full range
Full range
2 
50 
150
nA
10
pA/
°
C
Vo=1.4 V 
25 
°
C 
Full range
25° C 
Full range
-20 
-250 nA
-500
Vcc = 5 V to MAX 
0 to Vcc-1.5 
0 to Vcc - 2
V
R
L 
≥
2 
K
Vcc = MAX, R
L
=2 k
Vcc = MAX,
R
L 
≥
10 k
R
L  
≥
10 k
25 
°
C 
Full range
Full range
Vcc-1.5 
26
27
V
28
V
OL
Low-level output voltage
A
VD
Large-signal differential
voltage amplification
CMRR
Common-mode rejection ratio
k
SVR
 Supply voltage rejection
ratio (
Vcc/
V
IO
)
Vo1 /Vo2
Crosstalk attenuation
lo 
Output current
Full range
5
20
mV
Vcc = 15 V,
Vo=1V to 11 V,
R
L  
≥
2 k
Vcc = 5 V to MAX,
V
IC
 = V
ICR 
min
Vcc = 5 V to MAX 
25 
°
C 
25 
100 
V/mV
Full range
25 
°
C 
15
65 
80 
dB
25 
°
C 
65 
100 
dB
f=1 kHz to 20 kHz 
25 
°
C 
120 
dB
Vcc = 15 V, 
V
ID
=1 V,V
O
= 0
Vcc = 15 V, 
V
ID 
= -
 1 V, Vo = 15 V Full range
V
ID 
= -
 1 V,
Vo 
=
200 mV
Vcc at 5 V,
GND at -5 V,Vo=0
Vo - 2.5 V, No load
Vcc 
=
 MAX,
Vo 
=
 0.5Vcc, No load
25 
°
C 
Full range
25 
°
C 
-20 
-10
10 
5
12 
-30 
mA
20
25 
°
C 
30 
μ
A
l
OS
Short-circuit output current
I
CC
Supply current (two amplifiers)
25 
°
C 
±40 
±60 
mA
Full range
Full range
0.7
1
1.2
2
mA
* All characteristics are measured under open-loop conditions with zero common-mode input voltage unless otherwise
specified. MAX V
CC 
for testing purposes is 30 V. Full range is 0 
°
C to 70 
°
C.
4-2