Cassette Style
DC-DC Converters
M Series
Edition 01/01.2001
10/25
Table 6: Output response time tr and tf. Values not applicable for modules equipped with option E.
Type of converter
tr at Po = 0 and tf at Po = Po nom tr and tf at Po = 3/4 Po nom
tr at Po = Po nom
Unit
typ
max
typ
max
typ
max
A...LM 1001-7R and C/D/LMZ 1001-7R
5
10
5
10
20
ms
A...LM 1301-7R and C/D/LMZ 1301-7R
10
20
15
30
20
40
A...LM 1501-7R and C/D/LMZ 1501-7R
5
10
20
30
60
A...LM 1601-7R and C/D/LMZ 1601-7R
15
30
25
50
40
80
A...LM 1901-7R and C/D/LMZ 1901-7R
65
130
100
200
165
330
A...LM 2320-7 and C/D/LMZ 2320-7
20
40
30
60
50
100
A...LM 2540-7 and C/D/LMZ 2540-7
15
30
20
40
35
70
A...LM 3020-7 and C/D/LMZ 3020-7
55
110
85
170
145
290
A...LM 3040-7 and C/D/LMZ 3040-7
40
80
60
120
100
200
Conditions:
slowest. All outputs are resistively loaded. Variation of the input voltage within
Ui min...Ui max does not influence the values
considerably.
Table 7: Inhibit data
Characteristics
Conditions
min
typ
max
Unit
Uinh
Inhibit input voltage to keep
Uo = on
Ui min...Ui max
–50
0.8
V DC
output voltage
Uo = off
TC min...TC max
2.4
50
I inh
Inhibit current
Uinh = 0
–60
–100
–220
A
Auxiliary Functions
i Inhibit for Remote On and Off
Note: With open i input: Output is disabled (
Uo = off).
The outputs of the module may be enabled or disabled by
means of a logic signal (TTL, CMOS, etc.) applied between
the inhibit input i and the negative pin of output 1 (Vo1–). In
systems with several units, this feature can be used, for ex-
ample, to control the activation sequence of the converters.
If the inhibit function is not required, connect the inhibit pin
2 to pin 23 to enable the outputs (active low logic, fail safe).
For output response refer to:
Hold-up Time and Output Re-
sponse.
Vi+
Vi–
Vo–
i
Vo+
Iinh
Uinh
06031
1.6
0.8
0
–0.8
–50
Uinh [V]
Iinh [mA]
–30
0
–10
10
30
50
2.0
1.2
0.4
–0.4
Uinh = 0.8 V
Uo = on
Uo = off
Uinh = 2.4 V
06032
Fig. 9
Definition of Uinh and Iinh.
Fig. 10
Typical inhibit current Iinh versus inhibit voltage Uinh