Cassette Style
AC-DC Converters
KP Series
Edition 01/01.2001
15/23
Table 9: Temperature specications, values given are for an air pressure of 800...1200 hPa (800...1200 mbar)
Temperature
-5
-6
-7
Characteristics
Conditions
min
max
min
max
min
max
Unit
TA
Ambient temperature
U i min...U i max
–25
50
–25
60
–25
71
°C
TC
Case temperature
I o = 0...I o nom
–25
85
–25
90
–25
95
TS
Storage temperature
Not operational
–40
100
–40
100
–40
100
Immunity to Environmental Conditions
Test method
Standard
Test conditions
Status
Ca
Damp heat
IEC/DIN IEC 60068-2-3
Temperature:
40 ±2
°C
Unit not
steady state
MIL-STD-810D section 507.2
Relative humidity:
93 +2/-3 %
operating
Duration:
56 days
Ea
Shock
IEC/EN/DIN EN 60068-2-27
Acceleration amplitude:
100 gn = 981 m/s2
Unit
(half-sinusoidal)
MIL-STD-810D section 516.3
Bump duration:
6 ms
operating
Number of bumps:
18 (3 each direction)
Eb
Bump
IEC/EN/DIN EN 60068-2-29
Acceleration amplitude:
40 gn = 392 m/s2
Unit
(half-sinusoidal)
MIL-STD-810D section 516.3
Bump duration:
6 ms
operating
Number of bumps:
6000 (1000 each direction)
Fc
Vibration
IEC/EN/DIN EN 60068-2-6
Acceleration amplitude:
0.35 mm (10...60 Hz)
Unit
(sinusoidal)
5 gn = 49 m/s2 (60...2000 Hz)
operating
Frequency (1 Oct/min):
10...2000 Hz
Test duration:
7.5 h (2.5 h each axis)
Fn
Vibration
IEC 60068-2-64
Acceleration spectral density: 0.05 gn2/Hz
Unit
broad-band
DIN 40046 part 23
Frequency band:
5...500 Hz
operating
random
MIL-STD-810D section 514.3
Acceleration magnitude:
4.97 gn rms
(digital control)
Test duration:
3 h (1 h each axis)
Kb
Salt mist, cyclic
IEC/EN/DIN IEC 60068-2-52
Concentration:
5% (30
°C)
Unit not
(sodium chloride
Duration:
2 h per cycle
operating
NaCl solution)
Storage:
40
°C, 93% rel. humidity
Storage duration:
22 h per cycle
Number of cycles:
3
90
80
70
60
50
40
30
20
10
0
0.01
0.05
0.1
0.5
1
2
5
10
20
30
[dB
V]
MHz
0.02
07063
A
B
Fig. 20
Typical disturbance voltage (quasi-peak) at the input accord-
ing to CISPR 11/22 and EN 55011/22, measured at
Ui nom and Io nom.
50
40
30
20
10
0
30
50
100
200
500
1000
[dB
V/m]
[MHz]
A
B
07038
Fig. 21
Typical radiated electromagnetic field strength (quasi-peak)
according to CISPR 11/22 and EN 55011/22, normalized to
a distance of 10 m, measured at Ui nom and Io nom.