    參數(shù)資料
    型號: LKP5741-5EPD2B1
    元件分類: 電源模塊
    英文描述: 2-OUTPUT 250 W AC-DC PWR FACTOR CORR MODULE
    封裝: METAL, CASE K02, MODULE
    文件頁數(shù): 9/23頁
    文件大?。?/td> 534K
    代理商: LKP5741-5EPD2B1
    Cassette Style
    AC-DC Converters
    KP Series
    Edition 01/01.2001
    17/23
    Safety and Installation Instructions
    Connector Pin Allocation
    The connector pin allocation table defines the electrical
    potentials and the physical pin positions on the H15 con-
    nector. Pin no. 24, the protective earth pin present on all
    LKP AC-DC converters is leading, ensuring that it makes
    contact with the female connector first.
    Table 10: H15 connector pin allocation
    Pin
    Connector type H15
    No.
    LKP 5000
    4
    Vo2+
    Output 2
    6
    Vo2+
    Output 2
    8Vo2–
    Output 2
    10
    Vo2–
    Output 2
    12
    Vo1+
    Output 1
    14
    Vo1–
    Output 1
    16
    R 1
    Control of
    U o1
    18
    i
    Inhibit
    20
    D
    Save data
    22
    T
    Current sharing
    24 2
    Protective earth
    26
    N
    Neutral
    28
    N
    Neutral
    30
    P
    Phase
    32
    P
    Phase
    1 Feature R excludes option P and vice versa
    2 Leading pin (pregrounding)
    Fig. 24
    View of module's male connectors
    Protection Degree
    Condition: Female connector fitted to the unit.
    IP 30: All units except those with option P, and except
    those with option D with potentiometer.
    IP 20: All units fitted with option P, or with option D with
    potentiometer.
    4
    32
    10008
    Fixtures for connector retension
    clips V (see
    Accessory Products)
    Installation Instructions
    The KP series AC-DC converters are components, in-
    tended exclusively for inclusion within other equipment by
    an industrial assembly operation or by professional install-
    ers. Installation must strictly follow the national safety regu-
    lations in compliance with the enclosure, mounting,
    creepage, clearance, casualty, markings and segregation
    requirements of the end-use application.
    Connection to the system shall be made via the female con-
    nector H15 (see:
    Accessories). Other installation methods
    may not meet the safety requirements.
    The AC-DC converters are provided with pin no. 24 ( ),
    which is reliably connected with their case. For safety rea-
    sons it is essential to connect this pin with the protective
    earth of the supply system.
    An input fuse is built-in in the connection from pins no. 30
    and 32 (P~) of the unit. Since this fuse is designed to pro-
    tect the unit in case of an overcurrent and does not neces-
    sarily cover all customer needs, an external fuse suitable
    for the application and in compliance with the local require-
    ments might be necessary in the wiring to one or both input
    potentials, pins nos. 26 and 28 and/or nos. 30 and 32.
    Important: Whenever the inhibit function is not in use, pin
    no. 18 (i) should be connected to pin no. 14 (Vo1–) to en-
    able the output(s).
    Do not open the modules, or guarantee will be invali-
    dated.
    Due to high current values, all LKP units provide two inter-
    nally parallel connected contacts for certain paths (pins 4/6,
    8/10, 26/28 and 30/32, respectively). It is recommended to
    connect load and supply to both female connector pins of
    each path in order to keep the voltage drop across the con-
    nector pins to an absolute minimum and to not over-
    stress the connector contacts if currents are higher than
    approx. 8 A. The connector contacts are rated 8 A over the
    whole temperature range.
    Make sure there is sufficient air flow available for convec-
    tion cooling. This should be verified by measuring the case
    temperature when the unit is installed and operated in the
    end-use application. The maximum specified case tem-
    perature
    TC max shall not be exceeded. See also: Thermal
    Considerations.
    If the end-product is to be UL certified, the temperature of
    the main isolation transformer should be evaluated as part
    of the end-product investigation.
    Check for hazardous voltages before altering any connec-
    tions.
    The output provides a hazardous energy level according to
    IEC/EN 60950.
    Ensure that a unit failure (e.g. by an internal short-circuit)
    does not result in a hazardous condition. See also:
    Safety
    of operator accessible output circuit.
    Cleaning Agents
    In order to avoid possible damage, any penetration of
    cleaning fluids is to be prevented, since the power supplies
    are not hermetically sealed.
    相關PDF資料
    PDF描述
    LKP5742-7EPD3T 2-OUTPUT 250 W AC-DC PWR FACTOR CORR MODULE
    LKP5742-7PD4B1 2-OUTPUT 250 W AC-DC PWR FACTOR CORR MODULE
    LKP5742-7RD3B1 2-OUTPUT 250 W AC-DC PWR FACTOR CORR MODULE
    LKP5742-7RDDB1 2-OUTPUT 250 W AC-DC PWR FACTOR CORR MODULE
    LKP5741-5EPD8TB1 2-OUTPUT 250 W AC-DC PWR FACTOR CORR MODULE
    相關代理商/技術參數(shù)
    參數(shù)描述
    LKP5741-5R 制造商:Power-One 功能描述:AC/DC PS SGL-OUT 51.36V 5A 280W 15PIN - Bulk
    LKP5742-7R 制造商:Power-One 功能描述:AC/DC PS SGL-OUT 50.5V TO 56.5V 4A 226W 15PIN - Bulk
    LKQ1AF12TV5 制造商:Panasonic Electric Works 功能描述:PCB slim relay,SPNO,TV5,flux pf,5A 12Vdc
    LKQ1AF12TV5T 制造商:Panasonic Electric Works 功能描述:
    LKQ1AF12TV8 制造商:Panasonic Electric Works 功能描述:PCB slim relay,SPNO,TV8,flux pf,8A 12Vdc