![](http://datasheet.mmic.net.cn/30000/LW010F_datasheet_2358224/LW010F_24.png)
Data Sheet
August 1998
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W
LC/LW010- and LC/LW015-Series Power Modules:
Copyright 1998 Lucent Technologies Inc.
All Rights Reserved
Printed in U.S.A.
August 1998
DS98-040EPS (Replaces DS97-027EPS)
Printed On
Recycled Paper
For additional information, contact your Lucent Technologies Account Manager or the following:
POWER SYSTEMS UNIT: Network Products Group, Lucent Technologies Inc., 3000 Skyline Drive, Mesquite, TX 75149, USA
+1-800-526-7819 (Outside U.S.A.: +1-972-284-2626, FAX +1-972-284-2600) (product-related questions or technical assistance)
INTERNET:
http://www.lucent.com/networks/power
E-MAIL:
techsupport@lucent.com
ASIA PACIFIC:
Lucent Technologies Singapore Pte. Ltd., 750A Chai Chee Road #05-01, Chai Chee Industrial Park, Singapore 469001
Tel. (65) 240 8041, FAX (65) 240 8053
JAPAN:
Lucent Technologies Japan Ltd., 7-18, Higashi-Gotanda 2-chome, Shinagawa-ku, Tokyo 141-0022, Japan
Tel. (81) 3 5421 1600, FAX (81) 3 5421 1700
LATIN AMERICA: Lucent Technologies Inc., Room 9N128, One Alhambra Plaza, Coral Gables, FL 33134, USA
Tel. +1-305-569-4722, FAX +1-305-569-3820
EUROPE:
Data Requests: DATALINE: Tel. (44) 1189 324 299, FAX (44) 1189 328 148
Technical Inquiries:GERMANY: (49) 89 95086 0 (Munich), UNITED KINGDOM: (44) 1344 865 900 (Bracknell),
FRANCE: (33) 1 40 83 68 00 (Paris), SWEDEN: (46) 8 594 607 00 (Stockholm), FINLAND: (358) 9 4354 2800 (Helsinki),
ITALY: (39) 02 6608131 (Milan), SPAIN: (34) 91 807 1441 (Madrid)
Lucent Technologies Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No
rights under any patent accompany the sale of any such product(s) or information.
Ordering Information (continued)
Optional features may be ordered using the device code sufxes shown below. The feature sufxes are listed
numerically in descending order. Please contact your Lucent Technologies Account Manager or Application Engi-
neer for pricing and availability of options.
Table 7. Option Codes
Option
Device Code Sufx
Output voltage adjustment
9
Short pin: 2.8 mm
± 0.25 mm
(0.110 in.
± 0.010 in.)
8
Short pin: 3.7 mm
± 0.25 mm
(0.145 in.
± 0.010 in.)
6
Positive logic remote on/off
4
Synchronization
(cannot be ordered on units
with remote on/off)
3
Negative logic remote on/off
1