10
Lucent Technologies Inc.
Data Sheet
March 1997
L7554 Low-Power SLIC
Electrical Characteristics 
(continued)
Table 8. ac Feed Characteristics
1. Set by external components. Any complex impedance R
1
 + R2 || C between 150 
 and 1300 
 can be synthesized. 
2. This parameter is not tested in production. It is guaranteed by design and device characterization.
3. Return loss and transhybrid loss are functions of device gain accuracies and the external hybrid circuit. Guaranteed performance assumes 
1% tolerance of external components.
Parameter
Min
Typ
Max
Unit
ac Termination Impedance
1 
150
—
1300
Longitudinal Impedance
2
—
40
46
Total Harmonic Distortion—200 Hz to 4 kHz
2
  Off-hook
  On-hook
—
—
—
—
0.3
1.0
%
%
Transmit Gain, f = 1 kHz (PT/PR to VITR)
  Transmit Accuracy in dB, 25 
°
C
  Transmit Accuracy in dB, Full Temperature Range
—
–0.15
–0.22
–400
0
0
—
0.15
0.22
V/A
dB
dB
Receive + Gain, f = 1 kHz (RCVP to PT/PR)
Receive – Gain, f = 1 kHz (RCVN to PT/PR)
  Receive Accuracy in dB, 25 
°
C
  Receive Accuracy in dB, Full Temperature Range
—
—
–0.18
–0.25
8.00
–8.00
0
0
—
—
0.18
0.25
–
–
dB
dB
Gain vs. Frequency (transmit and receive)
  (600 
 termination; reference 1 kHz
2
)
  200 Hz to 300 Hz
  300 Hz to 3.4 kHz
  3.4 kHz to 16 kHz
  16 kHz to 266 kHz
–1.00
–0.3
–0.5
—
0.0
0.0
–0.1
—
0.05
0.05
0.3
2.0
dB
dB
dB
dB
Gain vs. Level (transmit and receive)(reference 0 dBV
2
)
  –50 dB to +3 dB
–0.05
0
0.05
dB
Return Loss
3
  200 Hz to 500 Hz
  500 Hz to 3400 Hz
2-wire Idle-channel Noise (600 
 termination)
  Psophometric
  C-message
  3 kHz Flat
20
26
24
29
—
—
dB
dB
—
—
—
–87
2
10
–77
12
20
dBmp
dBrnC
dBrn
Transmit Idle-channel Noise
  Psophometric
  C-message
  3 kHz flat
—
—
—
–82
7
15
–77
12
20
dBmp
dBrnC
dBrn
Transhybrid Loss
3
  200 Hz to 500 Hz
  500 Hz to 3400 Hz
21
26
24
29
—
—
dB
dB