c
2002
cosmo
ELECTRONICS CORPORATION
http://www.cosmo-ic.com
92
Features
1. Normally Open, Single Pole Single Throw
2. Control 350VAC or DC Voltage
3. Switch 130mA Loads
4. LED control Current, 5mA
5. Low ON-Resistance
6. dv/dt, >500V/ms
7. Isolation Test Voltage, 1500VACrms
UL
1577/
UL
508 (File No.E108430),
FI
EN60950 (File No.FI13698)
KAQW210S
High Voltage, Photo Mos Relay
E
D
Absolute Maximum Ratings
(Ta=25°C)
Emitter ( Input )
Reverse Voltage……………………………5.0V
Continuous Forward Current……………50mA
Peak Forward Current ………………………1A
Power Dissipation
……………………100mW
Derate Linearly from 25°C …………1.3mW/°C
Detector ( Output )
Output Breakdown Voltage ……………±350V
Continuous Load Current ……………±130mA
Power Dissipation
……………………500mW
General Characteristics
Isolation Test Voltage……………1500VACrms
Isolation Resistance
Vio=500V, Ta=25°C ……………………
≥
10
10
Total Power Dissipation ………………550mW
Derate Linearly from 25°C …………2.5mW/°C
Storage Temperature Range…-40°C to +125°C
Operating Temperature Range…-30°C to +85°C
Junction Temperature……………………100°C
Soldering Temperature,
2mm from case, 10 sec …………………260°C
KAQW210S
Unit : mm
TOLERANCE :
±
0.2mm
Turn on/ Turn off time
Mos Relay Schematic and Wiring Diagrams
Output
configuration
Type
Schematic
Load
Connection
Wiring Diagrams
KAQW210S
2a
AC/DC
–
Electro-optical Characteristics
(Ta=25°C)
Parameter
Emitter (Input)
Forward Voltage
Operation Input Current
Recovery Input Current
Detector (Output)
Output Breakdown Voltage
Output Off-State Leakage
I/O Capacitance
ON Resistance
Reverse (ON) Time
Operate (OFF) Time
Symbol
Conditions
Min.
Typ.
Max.
Unit
V
F
I
FON
I
FOFF
I
F
=10mA
1.2
1.5
5
V
V
L
=±20V, I
L
=100mA, t =10mS
V
L
=±20V, I
L
≤
5uA
mA
mA
0.2
V
B
I
TOFF
C
ISO
R
ON
T
ON
T
OFF
I
B
=50uA
350
V
uA
pF
ms
ms
V
T
=100V, I
F
=0mA
I
F
=0, f =1MH
Z
I
L
=100mA, I
F
=10mA
I
F
=10mA, V
L
=±20V
t =10ms, I
L
=±100mA
0.2
6
20
0.3
0.7
1
25
1.0
1.5
Hemar AG, Fendler 50, CH-5524 Nesselnbach, Tel: +41 (0)56 618 31 41, Fax +41 (0)56 618 31 42 http://www.hemar.ch