K9S2808V0C/B
28
SmartMedia
TM
K9S5608V0C/B
K9S6408V0C/B
READ ID
The device contains a product identification mode, initiated by writing 90h to the command register, followed by an address input of
00h. Three read cycles sequentially output the manufacture code(ECH), the device code (
K9S6408V0X : E6h , K9S2808V0X : 73h ,
K9S5608V0X: 75h
), the UniqueID code(A5h) respectively. The command register remains in Read ID mode until further commands are
issued to it. Figure 13 shows the operation sequence.
CE
CLE
I/O
0
~
7
ALE
RE
WE
90h
00h
Address. 1cycle
t
CEA
t
AR
t
REA
ECh
Maker code
75h
Device code
A5h
UniqueID code
t
CLR
t
WHR
K9S6408V0X : E6h
K9S2808V0X : 73h
Figure 14. RESET Operation
Table 4. Device Status
After Power-up
After Reset
Operation Mode
Read 1
Waiting for next command
FFh
I/O
0
~
7
R/B
t
RST
RESET
The device offers a reset feature, executed by writing FFh to the command register. When the device is in Busy state during random
read, program or erase mode, the reset operation will abort these operations. The contents of memory cells being altered are no
longer valid, as the data will be partially programmed or erased. The command register is cleared to wait for the next command, and
the Status Register is cleared to value C0h when WP is high. Refer to Table 4 for device status after reset operation. If the device is
already in reset state a new reset command will not be accepted by the command register. The R/B pin transitions to low for tRST
after the Reset command is written. Reset command is not necessary for normal operation. Refer to Figure 14 below.
Figure 13. Read ID Operation