JZ
66
5-(3). Electrical life test (TV power source)
Tested sample: JZ1aF-12V-TV, 10 pcs.
Load: AC 100 V TV power source
Inrush: 100 A max.; Steady: 5.0 A
Operating speed: 20 cpm
(ON:OFF = 1 s:2 s)
Ambient temperature: 40
°
C
104
°
F
95% R.H.
Circuit:
Change of pick-up and drop-out voltage
Change of contact resistance
AC
100 V
Mis-contacting
detection
Contact welding
detection
PC
board
40
°
C 95%R.H.
10
0
40
20
60
80
Max.
x
x
Min.
Min.
No. of operations,
×
10
4
C
Pick-up voltage
Drop-out voltage
10
0
30
10
20
40
50
No. of operations,
×
10
4
C
Max.
x
For Cautions for Use, see Relay Technical Information (Page 11 to 39).