4-(1). Coil temperature rise
Sample: 5 pcs., JS1-12V
Measured portion: Inside the coil
Contact current: 5 A
4-(2). Coil temperature rise
Sample: 5 pcs., JS1-12V
Measured portion: Inside the coil
Contact current: 10 A
5. Ambient temperature characteristics
Sample: 6 pcs., JS1-12V
80
120
100
140
10
20
30
40
0
Coil applied voltage, %V
T
°
C
°
C
50
°
C
25
°
C
80
120
100
140
10
20
30
40
0
50
°
C
70
°
C
25
°
C
Coil applied voltage, %V
T
°
C
–60–40 –20 0
20
20
10
–10
–20
40 60 80
Ambient
temperature
°
C
Pick-up voltage
Drop-out voltage
C
r
6. Electrical life test
(10 A 125 V AC, resistive load)
Sample: 6 pcs., JS1-12V
Operating speed: 20 cpm
Ambient temperature: room temperature
(Circuit)
Change of pick-up and drop-out voltage
Change of contact resistance
10A 125V AC
Contact welding
detection and
Mis-contacting
detection circuit
x
5
10
0
2
4
6
8
10
Max.
x
Max.
Min.
No. of operations,
×
10
4
P
Pick-up voltage
Drop-out voltage
10
5
0
60
20
40
80
100
Max.
xx
Min.
No. of operations,
×
10
4
C
Contact on the N.C. side
Contact on the N.O. side
For Cautions for Use, see Relay Technical Information (Page 11 to 39).