XSD Host Bus Interface
Communication with the host is achieved through XSD, a
light-weight subset of Intersil’s ISD single-wire bus interface.
XSD is a programmable-rate pseudo-synchronous
bidirectional host-initiated instruction-based serial
communication interface that allows up to two slave devices
to be attached and addressed separately. It includes
features to enable quick and reliable communication. The
communication protocol is optimized for efficient transfer of
data between the device and the host. The list below
outlines the features supported by the XSD bus interface:
Programmable bit rate up to 23kbps
Up to 2 devices can be connected to the host and
addressed separately
16-Bit host instruction frame supports multi-byte register
read and write
Built-in communication error detection
CRC generation capability
Supports interrupt signaling
Integrated bus inactivity detector for automatic activation
of sleep mode
XSD BUS PHYSICAL MODEL
The physical model of the XSD bus is shown in Figure 7.
The model shows a single-wire connection between the host
and the device, not including the ground signal. The input
logic on the device side is designed to be compatible with
any voltage between 1.8V to 5.0V. The host interface should
contain an open-drain or open-collector output. The pull-up
resister R
PU
can be connected either to the host supply
voltage V
DDH
or the device supply voltage V
DDD
. Typically
the host supply voltage should be used for pull-up.
DATA TRANSFER PROTOCOL
To initiate a transaction, the host first sends a 16-Bit
instruction frame to the device, followed by data byte
frame(s) if the instruction is a write operation. The instruction
frame consists of a chip-select code, operation code,
register bank and address pointer, and number of data bytes
information, as shown in Figure 9. If the instruction is a read
operation, the device will return 1 to 17 byte frames of data
back to the host. The serial data transfer always takes place
with the LSB first. The following explains the bus symbols
and the transaction frames are introduced in later sections.
BUS SIGNALING SYMBOLS
The XSD bus is nominally held high. Various bus symbols
and commands are generated by active-low pulse width
modulation. Following are the set of valid bus signaling
symbols supported by the XSD interface:
1) break (issued by host):
used to wake the device up from Sleep mode (Note: a
narrow ‘break’ can also be used to wake up the device
from the Sleep mode, as described in the Power-on Reset
section)
used to reset the device’s XSD bit counters and time
qualifiers
used to signal a change in communication channel (from
one slave device to another)
2) break (issued by device):
used as ‘device-ready’ indication to the host (after a
Soft-reset or wake up from Sleep mode)
used as an interrupt indicator
3) ‘1’ symbol:
used for instruction and data coding
4) ‘0’ symbol:
used for instruction and data coding
SYMBOL TIMING DEFINITIONS
Symbol timings are defined in terms of bit-time (BT),
determined by the selected bus transfer bit-rate
pre-programmed into the device’s OTP ROM location
0-00[5:4]. Selectable bus speeds are: 2.89kHz (x = 0.5),
5.78kHz (x = 1), 11.56kHz (x = 2) and 23.12kHz (x = 4).
An instruction or data frame consists of a sequence of ‘1’
and/or ‘0’ symbols. Figure 8 illustrates the timing definitions.
A ‘1’ symbol is nominally 0.3 BT wide while a ‘0’ symbol is
nominally 0.7 BT wide. One ‘1’ or ‘0’ symbol is represented
in each BT period. Any detected pulse width less than 0.124
BT wide will be interpreted as a glitch and will result in a bus
error. Table 2 and 3 summarize the timing definitions of all
TABLE 1. INTERRUPT EVENT SUMMARY
CONDITION
INTERRUPT
ENABLE BIT
INTERRUPT
STATUS FLAG
INTERRUPT EVENT
OTP ROM Write-in-
Progress
eEEW
(fixed)
sEEW
Accessing the ISL9206 during an on-going ROM write process (used only during initial
OTP ROM programming).
XSD Bus Error
eINT
sBER
XSD bus error or invalid instruction frame detected. Improper authentication sequence
detected.
Register Access
Error
eINT
sACC
Accessing protected registers.
ISL9206
相關(guān)PDF資料
PDF描述
ISL9206_07 FlexiHash+ For Battery Authentication
ISL9206DRZ-T FlexiHash+ For Battery Authentication
ISL9206EVAL1 FlexiHash For Battery Authentication
ISL9208IRZ Multi-Cell Li-ion Battery Pack OCP/Analog Front End
ISL9209B Charging System Safety Circuit
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ISL9206_07 制造商:INTERSIL 制造商全稱:Intersil Corporation 功能描述:FlexiHash+ For Battery Authentication
ISL9206A 制造商:INTERSIL 制造商全稱:Intersil Corporation 功能描述:FlexiHash+ For Battery Authentication
ISL9206ADHZR5335-060 制造商:Intersil Corporation 功能描述:- Bulk
ISL9206ADHZ-T 制造商:Intersil Corporation 功能描述:MULTI-CHEM 5PIN SOT-23 - Tape and Reel
ISL9206ADRTZ-T 制造商:Intersil Corporation 功能描述:MULTI-CHEM 8TDFN EP - Tape and Reel 制造商:Intersil Corporation 功能描述:IC, BATTERY AUTHENT, 2.6V-4.8V, TDFN-8, Supply Voltage Min:2.6V, Supply Voltage