3
Absolute Maximum Ratings
Recommended Operating Conditions
Storage Temperature Range . . . . . . . . . . . . . . . . . -65°C to + 125°C
Max Voltage V
IN
to Gnd. . . . . . . . . . . . . . . . . . . . . . . -0.5V to +6.5V
Max Voltage V
OUT
to Gnd
(*)
:
ISL60002, V
OUT
= 1.25V. . . . . . . . . . . . . . . . . . . . . -0.5V to +2.25V
ISL60002, V
OUT
= 2.50V. . . . . . . . . . . . . . . . . . . . . -0.5V to +3.50V
Voltage on “DNC” pins. . . . No connections permitted to these pins.
Lead Temperature, soldering
(*)
. . . . . . . . . . . . . . . . . . . . . . .+225°C
(*) note: maximum duration = 10 seconds
Temperature Range (Industrial). . . . . . . . . . . . . . . . . .-40°C to 85°C
ESD Ratings
Body test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5kV
CAUTION: Absolute Maximum Ratings are limits which may result in impaired reliability and/or permanent damage to the device. These are stress ratings provided for
information only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification are not
implied.
For guaranteed specifications and test conditions, see Electrical Characteristics.
The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed
test conditions.
Electrical Specifications ISL60002, V
OUT
= 1.25V
Operating Conditions: V
IN
= 3.0V, I
OUT
= 0mA, C
OUT
= 0.001μF, T
A
= -40 to
+85°C, unless otherwise specified.
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
V
OUT
Output Voltage
1.250
V
V
OA
V
OUT
Accuracy
T
A
= 25°C
ISL60002B12
-1.0
+1.0
mV
ISL60002C12
-2.5
+2.5
mV
ISL60002D12
-5.0
+5.0
mV
TC V
OUT
Output Voltage
Temperature Coefficient
(Note 1)
20
ppm/°C
V
IN
Input Voltage Range
2.7
5.5
V
I
IN
Supply Current
400
900
nA
V
OUT
/
V
IN
Line Regulation
+2.7V
≤
V
IN
≤
+5.5V
100
250
μV/V
V
OUT
/
I
OUT
Load Regulation
Sourcing: 0mA
≤
I
OUT
≤
7mA
25
60
μV/mA
Sinking: -7mA
≤
I
OUT
≤
0mA
25
60
μV/mA
V
OUT
/
t
Long Term Stability (Note 4)
T
A
= 25°C
10
ppm
√
1kHrs
V
OUT
/
T
A
Thermal Hysteresis (Note 2)
T
A
= 125°C
100
ppm
I
SC
Short Circuit Current (Note 3)
T
A
= 25°C, V
OUT
tied to Gnd
50
80
mA
V
N
Output Voltage Noise
0.1Hz
≤
f
≤
10Hz
30
μV
p-p
NOTES:
1. Over the specified temperature range. Temperature coefficient is measured by the box method whereby the change in V
OUT
is divided by the
temperature range; in this case, -40°C to +85°C = 125°C.
2. Thermal Hysteresis is the change in V
OUT
measured @ T
A
= 25°C after temperature cycling over a specified range,
T
A
. V
OUT
is read initially
at T
A
= 25°C for the device under test. The device is temperature cycled and a second V
OUT
measurement is taken at 25°C. The difference
between the initial V
OUT
reading and the second V
OUT
reading is then expressed in ppm. For
T
A
= 125°C, the device under is cycled from
+25°C to +85°C to -40°C to +25°C.
3. Guaranteed by device characterization and/or correlation to other device tests.
4. FGA voltage reference long term drift is a logarithmic characteristic. Changes that occur after the first few hundred hours of operation are
significantly smaller with time, asymptotically approaching zero beyond 2000 hours. Because of this decreasing characteristic, long-term drift is
specified in ppm/
√
1kHr.
ISL60002