Industrial Environment DC/DC Converters < 40W IMS6 Series
Electrical Output Data
General conditions:
T
A
= 25
C, unless
T
C
is specified.
Table 6a: Output data for single output units
Output
U
o nom
5.0 V
12.0 V
15.0 V
Characteristics
Conditions
min typ max
min typ max
min typ max
Unit
U
o
Output voltage
U
i nom,
I
o
= 0.5
I
o nom
4.96
5.04
11.90
12.10
14.88
15.12
VDC
I
o nom
Output current
U
i min
...
U
i max
U
i nom
,
T
C
= 25
C
1000
500
400
mA
I
o L
Current limit
2
1400
700
600
U
o U
Line regulation
U
i min
...
U
i max
,
I
o nom
1
3
1
3
1
3
%
U
Load regulation
U
i nom
I
o
= (0.1...1)
I
o nom
u
o1, 2
Output voltage noise
U
i min
...
U
i max
I
o
=
I
o nom
5
80
120
150
mV
pp
6
20
40
40
60
50
75
U
o clp
Output overvoltage
limitation
Min. load 1%
130
130
130
%
C
o ext
Admissible
capacitive load
3
680
150
100
uF
u
o d
Dynamic Voltage deviat.
load
Recovery time
regulat.
U
i nom
I
o nom
250
250
250
mV
t
d
1
/
2
I
o nom
1
1
ms
Uo
Temperature coefficient
U
o
/
T
C
U
i min
...
U
i max
I
o
= 0...
I
o nom
0.02
0.02
0.02
%/K
Table 6b: Output data for dual output units
Output
U
o nom
5 V
12 V
15 V
Characteristics
Conditions
min typ max
min typ max
min typ max
Unit
U
o1
U
o2
Output voltage
U
i nom
I
o1
=
I
o2
= 0.5
I
o nom
4.96
4.95
5.04
5.05
11.90
11.88
12.10
12.12
14.88
14.85
15.12
15.15
VDC
I
o nom
Output current
1
U
i min
...
U
i max
2
500
2
350
2
200
mA
U
o U
Line regulation
U
i min
...
U
i max
,
I
o nom
1
3
1
3.5
1
3
U
Load regulation
4
U
i nom
I
o
= (0.1...1)
I
o nom
u
o1, 2
Output voltage noise
U
i min
...
U
i max
I
o
=
I
o nom
5
100
140
150
mV
pp
6
40
60
45
70
50
75
U
o clp
Output overvoltage
limitation
Min. load 1%
130
130
130
%
C
o ext
Admissible
capacitive load
3
680
150
100
uF
u
o d
Dynamic Voltage deviat.
load
Recovery time
regulat.
U
i nom
I
o nom
250
600
750
mV
t
d
1
/
2
I
o nom
1
1
1
ms
Uo
Temperature coefficient
U
o
/
T
C
U
i min
...
U
i max
I
o
= 0...
I
o nom
0.02
0.02
0.02
%/K
1
Each output capable of delivering full output power.
2
The current limit is primary side controlled.
3
Sum of both outputs.
4
Conditions for specified output. Other output loaded with constant current
I
o
= 0.5
I
o nom
.
5
BW = 20 MHz
6
Measured with a probe according to EN 61204.
Edition 1 06.00
N/A
%
N/A
x
x
x