45
INDUSTRIAL
TEMPERATURE RANGES
SINGLE CHANNEL T1/E1/J1 LONG HAUL/SHORT HAUL LINE INTERFACE UNIT
Table-46 INTES: Interrupt Trigger Edge Select Register
(R/W, Address = 16H)
Symbol
Bit
Default
Description
EQ_IES
7
0
This bit determines the Equalizer out of range interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the EQ_S bit in the STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the EQ_S bit in the STAT0
status register.
IBLBA_IES
6
0
This bit determines the Inband Loopback Activate Code interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the IBLBA_S bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the IBLBA_S bit in STAT0
status register
IBLBD_IES
5
0
This bit determines the Inband Loopback Deactivate Code interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the IBLBD_S bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the IBLBD_S bit in STAT0
status register
PRBS_IES
4
0
This bit determines the PRBS/QRSS synchronization status interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the PRBS_S bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the PRBS_S bit in STAT0
status register
TCLK_IES
3
0
This bit determines the TCLK Loss interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the TCLK_LOS bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the TCLK_LOS bit in STAT0
status register
DF_IES
2
0
This bit determines the Driver Failure interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the DF_S bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the DF_S bit in STAT0 status
register
AIS_IES
1
0
This bit determines the AIS interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the AIS_S bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the AIS_S bit in STAT0 status
register
LOS_IES
0
This bit determines the LOS interrupt event.
= 0: Interrupt is generated as a ‘0’ to ‘1’ transition of the LOS_S bit in STAT0 status register
= 1: Interrupt is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the LOS_S bit in STAT0 status
register