DUAL SELECTABLE AC INPUT AC-DC 19" COMPATIBLE DOUBLE 
EUROCARD MULTIPLE OUTPUT 250-360 WATTS SWITCHING 
MODE POWER SUPPLIES HSU250, HSU300 & HSU360 SERIES
FEATURES: 
DUAL INPUT RANGE USER SELECTABLE 
DOUBLE OR TRIPLE CONVERTER 
ARCHITECTURE 
19" COMPATIBLE EUROCARD FORMAT 
MEET THE SAFETY STANDARDS 
EMI MEET CISPR PUB. 22 & FCC CLASS A 
CE MARKING COMPLIANCE 
6U X 12HP X 160MM DOUBLE EUROCARD 
VMEbus STANDARD 
GENERAL SPECIFICATION
Efficiency: 
Typ. 75-80.0%. 
Switching Frequency:
 Typ. 100K Hz. 
Circuit Topology:
 Forward circuit. 
HSU250/HSU300/HSU360 triple converter. 
HSU360T dual converter architecture. 
Transient Response:
 Typ. 3mS following a 25% load change.
Power Density:
 1.58 Watts / Cubic Inch for HSU250. 
1.90 Watts / Cubic Inch for HSU300. 
2.28 Watts / Cubic Inch for HSU360 & HSU360T.
Note: All measurements are at nominal input, full load, and +25°C unless otherwise specified. 
Operating Temperature: 
0 to +50°C at full load. Derates 
linearly to +70°C at half load. 
Storage Temperature: 
-20 to +85°C. 
Temperature Coefficient:
 Typ. 0.04%/°C. 
Cooling:
 At least 60cfm forced air flow is required  
for full load. 
Construction format:
 12HP(TE)x6Ux160mm  
19” compatible double Eurocard VMEbus standard.
Safety Standard:
 IEC950/UL1950 Class I. 
OUTPUT SPECIFICATION
Output Voltage:
 See Ratings Chart. 
Output Current:
 See Ratings Chart. 
Output Wattage:
 Typ. 250 Watts for HSU250. 
Typ. 300 Watts for HSU300. 
Typ. 360 Watts for HSU360/HSU360T. 
Output Connector:
 DIN 41612 at rear. 
Line Regulation:
 Typ. 0.4%. 
Load Regulation:
 VO1 typ. ±1.0%(Main). 
VO2 typ. ±1.0%(Main). 
VO3 typ. ±1.0%(Main). 
or typ. ±3.0%(PR) for HSU360T. 
Noise & Ripple:
 Typ. 1% peak to peak. 
OVP:
 Built-in at main VO1/VO2/VO3 (Latch). 
Adjustability:
 Available at main output VO1,VO2,VO3. 
Remote Sense:
 Installed at main VO1. 
Overload Protection (OLP):
 Fully protected against 
output overload and short circuit. 
Consult factory for OLP setting. 
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
 115Vac/230Vac dual selectable. 
Input Connector:
 DIN 41612 for HSU250/300/360T. 
IEC320 AC receptacle for HSU360. 
Input Frequency:
 47-63Hz 
Inrush Current:
 Typ. 65A @230Vac. 
Input Current: 
HSU250  6.0A@115Vac/3.0A@230Vac. 
HSU300  1.2A@115Vac/0.7A@230Vac. 
HSU360  6.5A@115Vac/3.5A@230Vac. 
HSU360T 6.2A@115Vac/3.0A@230Vac. 
Dielectric Withstand:
 Meet IEC950. 
EMI:
 Meet CISPR PUB. 22 & FCC Class A. 
Power Fail/OK:
 Option. 
Remote (Logic) Inhibit:
 Available. 
Hold-up Time:
 Typ. 20mS. 
Earth leakage:
 Typ. 0.3mA @230Vac. 
Over Temperature Protection (OTP):
 Option.